Calibrating ion density profile measurements in ion thruster beam plasma.

Rev Sci Instrum

Department of Astronautical Engineering, University of Southern California, Los Angeles, California 90089, USA.

Published: November 2016

The ion thruster beam plasma is characterized by high directed ion velocity (10 m/s) and low plasma density (10 m). Interpretation of measurements of such a plasma based on classical Langmuir probe theory can yield a large experimental error. This paper presents an indirect method to calibrate ion density determination in an ion thruster beam plasma using a Faraday probe, a retarding potential analyzer, and a Langmuir probe. This new method is applied to determine the plasma emitted from a 20-cm-diameter Kaufman ion thruster. The results show that the ion density calibrated by the new method can be as much as 40% less than that without any ion current density and ion velocity calibration.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4966912DOI Listing

Publication Analysis

Top Keywords

ion thruster
16
ion density
12
thruster beam
12
beam plasma
12
ion
9
ion velocity
8
langmuir probe
8
plasma
6
density
5
calibrating ion
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?