The newest generation of Gas Cherenkov Detector (GCD-3) employed in Inertial Confinement Fusion experiments at the Omega Laser Facility has provided improved performance over previous generations. Comparison of reaction histories measured using two different deuterium-tritium fusion products, namely gamma rays using GCD and neutrons using Neutron Temporal Diagnostic (NTD), have provided added credibility to both techniques. GCD-3 is now being brought to the National Ignition Facility (NIF) to supplement the existing Gamma Reaction History (GRH-6m) located 6 m from target chamber center (TCC). Initially it will be located in a reentrant well located 3.9 m from TCC. Data from GCD-3 will inform the design of a heavily-shielded "Super" GCD to be located as close as 20 cm from TCC. It will also provide a test-bed for faster optical detectors, potentially lowering the temporal resolution from the current ∼100 ps state-of-the-art photomultiplier tubes (PMT) to ∼10 ps Pulse Dilation PMT technology currently under development.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4962059DOI Listing

Publication Analysis

Top Keywords

national ignition
8
ignition facility
8
generation gamma-ray
4
gamma-ray cherenkov
4
cherenkov detectors
4
detectors national
4
facility newest
4
newest generation
4
generation gas
4
gas cherenkov
4

Similar Publications

Enterovirus A71 (EV-A71) has caused hand, foot, and mouth disease with an increased prevalence of neurological complications and acute mortality, threatening young children around the globe. By provoking mucosal immunity, intranasal vaccination has been suggested to prevent EV-A71 infection. However, antigens delivered via the nasal route usually fail to induce a protective memory response.

View Article and Find Full Text PDF

Cytosine-rich and poly(adenine)-tailed tetrahedral DNA framework (TDF) is designed as template (A-TDF) for anchoring silver nanoclusters (AgNCs) and igniting the dual-color fluorescence of AgNCs. The resultant DNA-AgNCs simultaneously emits red and green fluorescence, and the quantum yield of red fluorescence is as high as 44.8%.

View Article and Find Full Text PDF

Background: The role of direct oral anticoagulants (DOACs) in the treatment of left ventricular thrombus (LVT) after ST-elevation myocardial infarction (STEMI) remains uncertain.

Aims: We aimed to compare the effect of rivaroxaban versus warfarin in patients with STEMI complicated by LVT.

Methods: Adult patients with STEMI and two-dimensional transthoracic echocardiography showing LVT were assigned to rivaroxaban (15 mg once daily) or warfarin (international normalised ratio goal of 2.

View Article and Find Full Text PDF

The storage and release of energy is an economic cornerstone. In quantum dots (QDs), energy storage is mostly governed by their surfaces, in particular by surface chemistry and faceting. The impact of surface free energy (SFE) through surface faceting has already been studied in QDs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!