To investigate if there is any correlation between the bullet design and the respective dimensions of the abrasion collar and the skin defect in gunshot entrance wounds, experimental studies were performed on dyed pig skin. For the test shots, .38 Special revolver cartridges with three different bullet designs (round nose, wadcutter, and truncated cone) were used. With the help of an image editing program in combination with an image analyzing system, the area size of the abrasion rings and the skin defects was calculated automatically. The measured values differed significantly depending on the bullet type: the abrasion ring areas were largest in shots with round nose bullets and smallest with wadcutter projectiles. With regard to the entrance hole size, the relationship was inverse. The results are discussed with reference to the pertinent literature concerning the dynamic interaction between bullet and skin.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00414-016-1501-6 | DOI Listing |
Diagnostics (Basel)
December 2024
Faculty of Medicine and Surgery, "Kore" University of Enna, 94100 Enna, Italy.
: Firearm wounds tend to have a precise pattern. Despite this, real-world case presentations can present uncertain elements, sometimes deviating from what is considered standard, and present uncommon features that are difficult for forensic pathologists and ballistic experts to explain. : A retrospective analysis of autopsy reports from the Institute of Legal Medicine, University of Catania, covering 2019-2023, included 348 judicial inspections and 378 autopsies performed as part of the institute's overall activities.
View Article and Find Full Text PDFAm J Forensic Med Pathol
October 2024
Department of Pathology, Western Michigan University Homer Stryker MD School of Medicine, Kalamazoo, MI.
Forensic pathologists recognize the importance of estimating the range of fire for gunshot entrance wounds. Classically described ranges of fire include contact, close range, medium (or intermediate) range, and indeterminate (or distant) range. The presence or absence of gunshot residue (smoke/soot and/or gunpowder) and the characteristics of the gunshot residue are evaluated in order to estimate the range of fire.
View Article and Find Full Text PDFClin Ter
July 2024
Legal Medicine Section, Biomorf Department, Messina University, Messina, Italy.
Background: The use of radiological approaches in forensic investigations is rapidly emerging as an alternative to traditional autopsies. Here, we present the experience of the Sicilian and Calabrian forensic medical departments over the past five years, highlighting the application of PMCT to support autopsies in cases involving gunshot wound victims.
Materials And Methods: From January 2020 to March 2024, thirty cadavers who died from gunshot wounds underwent total body PMCT examinations followed by autopsies.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!