Objective: The present study was performed on cadavers to evaluate the efficacy of the different supraclavicular block techniques (Vongvises, Dalens, plumb-bob and inter-SCM) by investigating the location of the needle tip on the brachial plexus and to determine the most suitable block techniques according to the site of the surgery.

Methods: The study was performed on one embalmed and nine fresh cadavers. After the dissection, the skin of the cadavers was restored in its original position. Then, they are positioned, and the needle was inserted according to the technique described by the authors in the original articles. The distances between the needle tip and the three trunks were measured, and the location of the needle tip on the brachial plexus was determined.

Results: A significant difference in the proximity of the needle tip to the middle of the middle truncus was noted only in the inter-SCM technique compared with the Dalens technique at both sides (p<0.05).

Conclusion: In our study, the distance between the needle tip and truncus medius was the shortest in the plumb-bob technique at both sides. Both in the plumb-bob and inter-SCM techniques, the distribution of the needle tip over the trunci of the plexus brachialis was homogenous. In Dalens technique, the needle tip reached the truncus superior or between the truncus superior and n. suprascapularis in 95% of the cases. Further, we concluded that moving the insertion point approximately 1 cm caudal and maintaining the anteroposterior needle direction in the Vongvises technique would result in a successful brachial plexus block.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5019867PMC
http://dx.doi.org/10.5152/TJAR.2016.81084DOI Listing

Publication Analysis

Top Keywords

location needle
12
block techniques
12
supraclavicular block
8
study performed
8
needle brachial
8
brachial plexus
8
needle
5
needle tips
4
tips plexus
4
plexus brachialis
4

Similar Publications

Background: Endobronchial ultrasound guided Transbronchial Needle Aspiration (EBUS-TBNA) is the predominant method for investigation of centrally located solitary pulmonary nodules. The method is associated with good to excellent diagnostic sensitivity and specificity with the positive predictive value of the test reaching 100% and reported negative predictive values for FNA of pulmonary nodules ranging from 53% to 97%. The impact of correlating cytologic results with imaging and clinical findings for improvement of negative predictive value has been poorly studied.

View Article and Find Full Text PDF

Monitoring deep wounds is challenging but necessary for high-quality medical treatment. Current methodologies for deep wound monitoring are typically limited to indirect clinical symptoms or costly non-real-time imaging diagnosis. Herein, a smart system is proposed that enables in situ monitoring of deep wounds' status through a semi-implantable device composed of 2 seamlessly connected functional components: 1) the well-designed, microchannel-structured sampling needles that efficiently and conveniently collect samples from deep wound anatomical locations, and 2) the multiplex biochemical testing compartment that facilitates the immediate and persistent detection of multiple biochemical indicators based on a color image processing software accessible to a conventional smartphone.

View Article and Find Full Text PDF

Background: Percutaneous vertebroplasty (PVP) is a common surgical method for osteoporotic vertebral compression fracture (OVCFs). The puncture method and location of the puncture needle can directly affect bone cement distribution in the vertebra. This retrospective study aimed to compare the clinical efficacy and safety of PVP using the cross-puncture and bilateral conventional puncture for the treatment of Genant grade 0-1 OVCFs.

View Article and Find Full Text PDF

Cutting tools with orderly arranged diamond grits using additive manufacturing show better sharpness and longer service life than traditional diamond tools. A retractable needle jig with vacuum negative pressure was used to absorb and place grits in an orderly arranged manner. However, needle hole wear after a long service time could not promise complete grit adsorption forever.

View Article and Find Full Text PDF

Neuraxial Anesthesia and Risk of Root Damage: A 3D Ex Vivo Study.

NeuroSci

December 2024

Laboratory of Surgical Neuroanatomy (LSNA), Human Anatomy and Embryology Unit, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08036 Barcelona, Spain.

Cauda equina nerve roots may become damaged during neuraxial anesthesia, and post-puncture headache may appear in the case of cerebrospinal fluid leakage if needle tips are deformed due to bone contact when several attempts are needed. Our aim was to verify the correlation between skin-transverse process distance (st) and skin-dural sac distance (d) for calculation of optimal angles in a free visual guide and as a reference for the maximal depth to be traversed by the needle. Randomly selected ex vivo samples ( = 10) were flexed to reproduce the position of the lumbosacral spine during spinal anesthesia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!