OBJECTIVE To evaluate the validity of 2 radiographic methods for measurement of the tibial tuberosity advancement distance required to achieve a reduction in patellar tendon-tibial plateau angle (PTA) to the ideal 90° in dogs by use of the modified Maquet technique (MMT). SAMPLE 24 stifle joints harvested from 12 canine cadavers. PROCEDURES Radiographs of stifle joints placed at 135° in the true lateral position were used to measure the required tibial tuberosity advancement distance with the conventional (A) and correction (A) methods. The MMT was used to successively advance the tibial crest to A and A. Postoperative PTA was measured on a mediolateral radiograph for each advancement measurement method. If none of the measurements were close to 90°, the advancement distance was modified until the PTA was equal to 90° within 0.1°, and the true advancement distance (TA) was measured. Results were used to determine the optimal commercially available size of cage implant that would be used in a clinical situation. RESULTS Median A and A were 10.6 mm and 11.5 mm, respectively. Mean PTAs for the conventional and correction methods were 93.4° and 92.3°, respectively, and differed significantly from 90°. Median TA was 13.5 mm. The A and A led to the same cage size recommendations as for TA for only 1 and 4 stifle joints, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Both radiographic methods of measuring the distance required to advance the tibial tuberosity in dogs led to an under-reduction in postoperative PTA when the MMT was used. A new, more accurate radiographic method needs to be developed.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.77.12.1401DOI Listing

Publication Analysis

Top Keywords

advancement distance
24
distance required
12
tibial tuberosity
12
stifle joints
12
true advancement
8
patellar tendon-tibial
8
tendon-tibial plateau
8
plateau angle
8
ideal 90°
8
90° dogs
8

Similar Publications

This study presents an advanced methodology for 3D heart reconstruction using a combination of deep learning models and computational techniques, addressing critical challenges in cardiac modeling and segmentation. A multi-dataset approach was employed, including data from the UK Biobank, MICCAI Multi-Modality Whole Heart Segmentation (MM-WHS) challenge, and clinical datasets of congenital heart disease. Preprocessing steps involved segmentation, intensity normalization, and mesh generation, while the reconstruction was performed using a blend of statistical shape modeling (SSM), graph convolutional networks (GCNs), and progressive GANs.

View Article and Find Full Text PDF

To assess the choroidal vessels in healthy eyes using a novel three-dimensional (3D) deep learning approach. In this cross-sectional retrospective study, swept-source OCT 6 × 6 mm scans on Plex Elite 9000 device were obtained. Automated segmentation of the choroidal layer was achieved using a deep-learning ResUNet model along with a volumetric smoothing approach.

View Article and Find Full Text PDF

The coherent spin waves, magnons, can propagate without accompanying charge transports and Joule heat dissipation. Room-temperature and long-distance spin waves propagating within nanoscale spin channels are considered promising for integrated magnonic applications, but experimentally challenging. Here we report that long-distance propagation of chiral magnonic edge states can be achieved at room temperature in manganite thin films with long, antiferromagnetically coupled spin spirals (millimetre length) and low magnetic Gilbert damping (~3.

View Article and Find Full Text PDF

Recent progress in biopolymer-based electrospun nanofibers and their potential biomedical applications: A review.

Int J Biol Macromol

January 2025

School of Chemical Engineering, Yeungnam University, 280-Daehak-ro, Gyeongsan 38541, Republic of Korea. Electronic address:

Tissue engineering offers an alternative approach to developing biological substitutes that restore, maintain, or enhance tissue functionality by integrating principles from medicine, biology, and engineering. In this context, biopolymer-based electrospun nanofibers have emerged as attractive platforms due to their superior physicochemical properties, including excellent biocompatibility, non-toxicity, and desirable biodegradability, compared to synthetic polymers. Considerable efforts have been dedicated to developing suitable substitutes for various biomedical applications, with electrospinning receiving considerable attention as a versatile technique for fabricating nanofibrous platforms.

View Article and Find Full Text PDF

Introduction: Perilunate dislocations (PLD) and perilunate fracture-dislocations (PLFD) are high-energy wrist injuries often linked to significant post-traumatic osteoarthritis. This study aims to determine whether PLD and PLFD yield different radiological outcomes following surgical treatment while identifying prognostic factors for worse outcomes.

Materials And Methods: We retrospectively analyzed 51 patients treated for perilunate injuries between 2000 and 2022.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!