A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Occupational exposure limits for manufactured nanomaterials, a systematic review. | LitMetric

Background: The toxicological properties of manufactured nanomaterials (MNMs) can be different from their bulk-material and uncertainty remains about the adverse health effects they may have on humans. Proposals for OELs have been put forward which can be useful for risk management and workers' protection. We performed a systematic review of proposals for OELs for MNMs to better understand the extent of such proposals, as well as their derivation methods.

Methods: We searched PubMed and Embase with an extensive search string and also assessed the references in the included studies. Two authors extracted the data independently.

Results: We identified 20 studies that proposed in total 56 OEL values. Of these, two proposed a generic level for all MNMs, 14 proposed a generic OEL for a category of MNMs and 40 proposed an OEL for a specific nanomaterial. For specific fibers, four studies proposed a similar value but for carbon nanotubes (CNTs) the values differed with a factor ranging from 30 to 50 and for metals with a factor from 100 to 300. The studies did not provide explanations for this variation. We found that exposure to MNMs measured at selected workplaces may exceed even the highest proposed OEL. This indicates that the application and use of OELs may be useful for exposure reduction.

Conclusion: OELs can provide a valuable reference point for exposure reduction measures in workplaces. There is a need for more and better supported OELs based on a more systematic approach to OEL derivation.

Download full-text PDF

Source
http://dx.doi.org/10.1080/17435390.2016.1262920DOI Listing

Publication Analysis

Top Keywords

manufactured nanomaterials
8
systematic review
8
proposals oels
8
studies proposed
8
proposed generic
8
mnms proposed
8
proposed oel
8
proposed
6
mnms
5
oels
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!