Previous research on the accuracy of flapless implant placement of virtually planned implants in the augmented maxilla revealed unfavourable discrepancies between implant planning and placement. By using the osteosynthesis screws placed during the augmentation procedure, the surgical template could be optimally stabilized. The purpose of this study was to validate this method by evaluating its clinically relevant accuracy. Twelve consecutive fully edentulous patients with extreme resorption of the maxilla were treated with a bone augmentation procedure. Virtual implant planning was performed and a surgical template was manufactured. Subsequently, six implants were installed using the surgical template, which was only supported by the osteosynthesis screws. Implant deviations between planning and placement were calculated. A total of 72 implants were installed. Mean deviations found in the mesiodistal direction were 0.817mm at the implant tip and 0.528mm at the implant shoulder. The angular deviation was 2.924°. In the buccolingual direction, a deviation of 1.038mm was registered at the implant tip and 0.633mm at the implant shoulder. The angular deviation was 3.440°. This study showed that implant placement in the augmented maxilla using a surgical template supported by osteosynthesis screws is accurate.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijom.2016.10.013DOI Listing

Publication Analysis

Top Keywords

osteosynthesis screws
16
surgical template
16
implant placement
12
augmented maxilla
12
implant
10
placement augmented
8
implant planning
8
planning placement
8
augmentation procedure
8
implants installed
8

Similar Publications

Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.

View Article and Find Full Text PDF

Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.

View Article and Find Full Text PDF

Background: While there have been significant advancements in recent years, complications following fixation for femoral neck fractures remain a concern. This retrospective cohort study aimed to investigate the influence of polytrauma and additional fractures on the occurrence of complications in patients who underwent surgical fixation for femoral neck fractures. The study focused on analyzing patient demographics, comorbidities, fracture classifications, fixation methods, and the likelihood of experiencing post-operative complications, with a specific emphasis on the impact of polytrauma and additional fractures.

View Article and Find Full Text PDF

Background: The standard approach for addressing intra-articular calcaneal fractures involves open reduction with plate and screw fixation, with ongoing discourse regarding the application of grafts to address bone gaps. The aim of this study is the temporal comparison of the radiological and functional outcomes in patients undergoing surgery for intra-articular calcaneal fractures, with a specific focus on the use of bone grafts.

Methods: Thirty patients, comprising 13 with iliac grafts and 17 without, were enrolled in the study.

View Article and Find Full Text PDF

Introduction: Distal femur fractures present significant surgical challenges due to their complex anatomy and limited soft tissue coverage. Minimally invasive plate osteosynthesis (MIPO) has emerged as a promising alternative to traditional open techniques, aiming to reduce soft-tissue damage while maintaining stable fixation, particularly when used with locking plates.

Materials And Methods: This retrospective study analyzed 40 consecutive patients with distal femur fractures treated with MIPO and locking plates.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!