[Radiological dose and metadata management].

Radiologe

Ärztliche Stelle für Qualitätssicherung in der Radiologie, Nuklearmedizin und Strahlentherapie Hessen, TÜV SÜD Life Service GmbH, Am Römerhof 15, 60486, Frankfurt, Deutschland.

Published: December 2016

This article describes the features of management systems currently available in Germany for extraction, registration and evaluation of metadata from radiological examinations, particularly in the digital imaging and communications in medicine (DICOM) environment. In addition, the probable relevant developments in this area concerning radiation protection legislation, terminology, standardization and information technology are presented.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00117-016-0190-yDOI Listing

Publication Analysis

Top Keywords

[radiological dose
4
dose metadata
4
metadata management]
4
management] article
4
article describes
4
describes features
4
features management
4
management systems
4
systems currently
4
currently germany
4

Similar Publications

A Phase II Trial of Onapristone and Fulvestrant for Patients With ER+ and HER2- Metastatic Breast Cancer.

Clin Breast Cancer

December 2024

Medical Oncology and Palliative Care, Department of Medicine, Breast Cancer Disease Oriented Team, University of Wisconsin Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health, Madison, WI 53792-3252.

Background: The SMILE study is a multi-institutional phase II clinical trial to determine the efficacy and safety of an antiprogestin, onapristone, in combination with fulvestrant as second-line therapy for patients with ER+, PgR+/-, HER2- metastatic breast cancer. This study was terminated early and herein, we report patient characteristics, and outcomes.

Methods: Eligibility criteria included disease progression on ≥2 lines of prior therapy, ECOG performance status ≤ 2, measurable disease per RECIST 1.

View Article and Find Full Text PDF

Purpose: BMS-986299 is a first-in-class, NOD-, LRR-, and pyrin-domain containing-3 (NLRP3) inflammasome agonist enhancing adaptive immune and T-cell memory responses.

Materials And Methods: This was a phase-I (NCT03444753) study that assessed the safety and tolerability of intra-tumoral BMS-986299 monotherapy (part 1A) and in combination (part 1B) with nivolumab, and ipilimumab in advanced solid tumors. Reported here are single-center results.

View Article and Find Full Text PDF

Multi-layer shielding optimization of a high activity Am-Be mixed field irradiation facility.

Appl Radiat Isot

January 2025

Experimental Nuclear Physics Department, Nuclear Research Centre, Egyptian Atomic Energy Authority, Egypt; Cyclotron Facility, Egyptian Atomic Energy Authority, Egypt.

Neutron and gamma-ray shielding design for a 30Ci (1.11TBq) Am-Be irradiation facility is studied using MCNP5 Monte Carlo simulation code. The study focuses on the optimization of the shielding layers of the previously planned neutron irradiation facility.

View Article and Find Full Text PDF

Objective: The study aims to systematically characterize the effect of CT parameter variations on images and lung radiomic and deep features, and to evaluate the ability of different image harmonization methods to mitigate the observed variations.

Approach: A retrospective in-house sinogram dataset of 100 low-dose chest CT scans was reconstructed by varying radiation dose (100%, 25%, 10%) and reconstruction kernels (smooth, medium, sharp). A set of image processing, convolutional neural network (CNNs), and generative adversarial network-based (GANs) methods were trained to harmonize all image conditions to a reference condition (100% dose, medium kernel).

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!