[The speech audiometry using the matrix sentence test].

Vestn Otorinolaringol

Medical Physics and Cluster of Excellence Hearing4all, Carl-von-Ossietzky, University Oldenburg, 26129, Oldenburg, Germany.

Published: March 2017

The matrix sentence test in which the five-word semantically unpredictable sentences presented under the background noise conditions are used as the speech material was designed and validated for many languages. The objective of the present study was to evaluate the Russian version of the matrix sentence test (RuMatrix test) in the listeners of different ages with normal hearing. At the first stage of the study, 35 listeners at the age from 18 to 33 year were examined. The results of the estimation of the training effect dictated the necessity of conducting two training tracks before carrying out the RuMatrix test proper. The signal-to-noise ratio at which 50% speech recognition (SRT50) was obtained was found to be -8.8±0.8 dB SNR. A significant effect of exposure to the background noise was demonstrated: the noise level of 80 and 75 Db SPL led to a considerably lower intelligibility than the noise levels in the range from 45 to 70 dB SPL; in the subsequent studies, the noise level of 65 dB SPL was used. The high test-retest reliability of the RuMatrix test was proved. At the second stage of the study, 20 young (20-40 year old) listeners and 20 aged (62-74 year old) ones were examined. The mean SRT50 in the aged patients was found to be -6.9±1.1 dB SNR which was much worse than the mean STR50 in the young subjects (-8.7±0.9 dB SNR). It is concluded that, bearing in mind the excellent comparability of the results of the RUMat rix test across different languages, it can be used as a universal tool in international research projects.

Download full-text PDF

Source
http://dx.doi.org/10.17116/otorino201681540-44DOI Listing

Publication Analysis

Top Keywords

matrix sentence
12
rumatrix test
12
sentence test
8
background noise
8
stage study
8
year examined
8
noise level
8
level spl
8
test
6
noise
5

Similar Publications

Cognitive decline and hearing loss are common in older adults and often co-occur while investigated separately, affecting the neural processing of speech. This study investigated the interaction between cognitive decline, hearing loss, and contextual cues in speech processing. Participants aged 60 years and older were assessed for cognitive decline using the Montreal Cognitive Assessment and for hearing ability using a four-frequency pure tone average.

View Article and Find Full Text PDF

Objectives: While single-sided deafness cochlear implants (SSD-CIs) have now received regulatory approval in the United States, candidate-ear candidacy criteria (no better than 5% word-recognition score) are stricter than for traditional CI candidates (50 to 60% speech recognition, best-aided condition). SSD implantation in our center began before regulatory approval, using a criterion derived from traditional candidacy: 50% consonant-nucleus-consonant (CNC) word-identification score in the candidate ear. A retrospective analysis investigated whether SSD patients exceeding the 5% CNC criterion nevertheless benefitted from a CI as assessed by spatial-hearing tests (speech understanding in noise [SIN] and localization) and by a patient-reported outcome measure quality-of-life instrument validated for patients with CIs.

View Article and Find Full Text PDF

The quest for noninvasive early markers for sensorineural hearing loss (SNHL) has yielded diverse measures of interest. However, comprehensive studies evaluating the test-retest reliability of multiple measures and stimuli within a single study are scarce, and a standardized clinical protocol for robust early markers of SNHL remains elusive. To address these gaps, this study explores the intra-subject variability of various potential electroencephalogram- (EEG-) biomarkers for cochlear synaptopathy (CS) and other SNHL-markers in the same individuals.

View Article and Find Full Text PDF

Introduction: Hearing aid (HA) manufacturers have introduced behind-the-ear (BTE) models where the microphone is positioned in the ear canal, which could impact auditory performance by distorting the pinna's acoustic cues. This study aimed to compare two different BTE HAs with varying microphone positions: the receiver in the ear (RITE) and the transducer in the ear (TIE).

Methods: The study involved 10 participants who had never used HAs before.

View Article and Find Full Text PDF

Electronic Health Records (EHRs) contain various valuable medical entities and their relationships. Although the extraction of biomedical relationships has achieved good results in the mining of electronic health records and the construction of biomedical knowledge bases, there are still some problems. There may be implied complex associations between entities and relationships in overlapping triplets, and ignoring these interactions may lead to a decrease in the accuracy of entity extraction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!