Intraobserver error (INTRA-OE) is the difference between repeated measurements of the same variable made by the same observer. The objective of this work was to evaluate INTRA-OE from 3D landmarks registered with a Microscribe, in different datasets: (A) the 3D coordinates, (B) linear measurements calculated from A, and (C) the six-first principal component axes. INTRA-OE was analyzed by digitizing 42 landmarks from 23 skulls in three events two weeks apart from each other. Systematic error was tested through repeated measures ANOVA (ANOVA-RM), while random error through intraclass correlation coefficient. Results showed that the largest differences between the three observations were found in the first dataset. Some anatomical points like nasion, ectoconchion, temporosphenoparietal, asterion, and temporomandibular presented the highest INTRA-OE. In the second dataset, local distances had higher INTRA-OE than global distances while the third dataset showed the lowest INTRA-OE.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/1556-4029.13301 | DOI Listing |
Forensic Sci Int
January 2020
Department of Anatomy, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa; Department of Anatomy, School of Medicine, Sefako Makgatho Health Sciences University, Ga-Rankuwa, Pretoria, South Africa. Electronic address:
Manual landmarking is used in several manual and semi-automated prediction guidelines for approximation of the nose. The manual placement of landmarks may, however, render the analysis less repeatable due to observer subjectivity and, consequently, have an impact on the accuracy of the human facial approximation. In order to address this subjectivity and thereby improve facial approximations, we are developing an automated three-dimensional (3D) method based on an automatic dense landmarking procedure using non-rigid surface registration.
View Article and Find Full Text PDFJ Forensic Sci
May 2017
DFG Center for Advanced Studies, University of Tübingen, Rümelinstraße 23, Tubingen, 72070, Germany.
Intraobserver error (INTRA-OE) is the difference between repeated measurements of the same variable made by the same observer. The objective of this work was to evaluate INTRA-OE from 3D landmarks registered with a Microscribe, in different datasets: (A) the 3D coordinates, (B) linear measurements calculated from A, and (C) the six-first principal component axes. INTRA-OE was analyzed by digitizing 42 landmarks from 23 skulls in three events two weeks apart from each other.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!