A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Large Omnidirectional Child (LODC) ATD: Biofidelity Comparison with the Hybrid III 10 Year Old. | LitMetric

When the Hybrid III 10-year old (HIII-10C) anthropomorphic test device (ATD) was adopted into Code of Federal Regulations (CFR) 49 Part 572 as the best available tool for evaluating large belt-positioning booster seats in Federal Motor Vehicle Safety Standard (FMVSS) No. 213, NHTSA stated that research activities would continue to improve the performance of the HIII-10C to address biofidelity concerns. A significant part of this effort has been NHTSA's in-house development of the Large Omnidirectional Child (LODC) ATD. This prototype ATD is comprised of (1) a head with pediatric mass properties, (2) a neck that produces head lag with Zaxis rotation at the atlanto-occipital joint, (3) a flexible thoracic spine, (4) multi-point thoracic deflection measurement capability, (5) skeletal anthropometry representative of a seated child, and (6) an abdomen that can directly measure belt loading. The objective of this study was to evaluate the LODC by comparing its body region and full-body responses to both standard HIII-10C responses and pediatric biomechanical data. In body region tests, the LODC (BioRank = 1.21) showed improved biofidelity over the HIII-10C (BioRank = 2.70). The LODC also exhibited kinematics more similar to pediatric PMHS kinematics in a reconstruction test. In FMVSS No. 213 tests, the LODC was observed to have lower HIC values with the absence of hard chin-to-chest contacts, indicating that chin-to-chest contact severity is mitigated in the LODC design. LODC abdomen pressures and belt penetrations discriminated between restraint conditions. These results suggest the LODC has biofidelic characteristics that make it a candidate for improved assessment of injury risk in restraint system development.

Download full-text PDF

Source
http://dx.doi.org/10.4271/2016-22-0017DOI Listing

Publication Analysis

Top Keywords

lodc
9
large omnidirectional
8
omnidirectional child
8
child lodc
8
lodc atd
8
hybrid iii
8
fmvss 213
8
body region
8
tests lodc
8
atd
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!