Comparison of lower limb and trunk kinematics between markerless and marker-based motion capture systems.

Gait Posture

La Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, La Trobe University, Melbourne, Australia.

Published: February 2017

AI Article Synopsis

Article Abstract

Unlabelled: Three dimensional (3-D) motion capture systems are used by researchers and clinicians to analyze the kinematics of human movement. Traditional marker based systems are time consuming and limit the size of studies. Markerless 3-D systems are quicker to use but the differences between data captured in each system is unclear.

Aim: To examine the relationship of kinematic data captured by marker based and markerless motion capture systems.

Methods: Movement was assessed in two tests: a simple knee flexion test and single leg squat with a marker based protocol (Vicon) and a markerless protocol (Organic Motion).

Results: There was no significant difference between protocols in knee flexion angle (p=0.33). In single leg squat there was no significant difference in 9 of 13 clinically relevant joint angles in the change in angle from the start to the peak of squat. There were significant differences in the angle at the peak of the squat for 9 of 13 joint angles.

Discussion: This study provides evidence that a marker-based and a markerless protocol report similar ranges of change in angle from the start of a squat to peak squat in the pelvis and lower limb in single leg squat. Specific joint angles should not be compared between protocols.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gaitpost.2016.10.020DOI Listing

Publication Analysis

Top Keywords

motion capture
12
marker based
12
single leg
12
leg squat
12
peak squat
12
lower limb
8
capture systems
8
data captured
8
knee flexion
8
markerless protocol
8

Similar Publications

The KinaTrax markerless motion capture system, used extensively in the analysis of baseball pitching and hitting, is currently being adapted for use in clinical biomechanics. In clinical and laboratory environments, repeatability is inherent to the quality of any diagnostic tool. The KinaTrax system was assessed on within- and between-session reliability for gait kinematic and spatiotemporal parameters in healthy adults.

View Article and Find Full Text PDF

Why do patients with isolated PCL rupture experience no subjective knee joint instability during walking? An biomechanical study.

Front Bioeng Biotechnol

January 2025

Department of Orthopaedics, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical Universit, Guangzhou, China.

Objective: The aim of this study is to assess the kinematic changes in the knee joint during walking in patients with isolated PCL-deficiency (PCLD) to determine the presence of walking-related joint instability (mechanical instability-abnormal displacement form structural damage). Additionally, the study seeks to provide biomechanical insights into the observed differences between subjective and objective assessments.

Methods: 35 healthy volunteers and 27 patients with isolated PCLD (both involved and uninvolved sides) were included in the study.

View Article and Find Full Text PDF

It is important in the rising demands to have efficient anomaly detection in camera surveillance systems for improving public safety in a complex environment. Most of the available methods usually fail to capture the long-term temporal dependencies and spatial correlations, especially in dynamic multi-camera settings. Also, many traditional methods rely heavily on large labeled datasets, generalizing poorly when encountering unseen anomalies in the process.

View Article and Find Full Text PDF

Background: Elbow injuries are prevalent among professional baseball pitchers as nearly 25% undergo ulnar collateral ligament reconstruction. Pitch type, ball velocity, and spin rate have been previously hypothesized to influence elbow varus torque and subsequent risk of injury, but existing research is inconclusive.

Purpose: To examine elbow varus torque, cumulative torque, and loading rate within professional pitchers throwing fastball, curveball, change-up, and slider pitches, as well as to identify potential influences of ball spin on the elbow.

View Article and Find Full Text PDF

Background: Vojta Therapy (VT) is a neurorehabilitation approach that targets ontogenetic postural function and automatic body posture control. Research has shown its potential to enhance gait ability. However, limited evidence exists regarding its immediate effects on individuals with Down syndrome (DS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!