Objectives: We hypothesized that negligible surgical material cost variation exists between traumatolgists for treatment of bimalleolar ankle and bicondylar tibial plateau fractures.

Design: Retrospective medical record review.

Setting: Academic level 1 Trauma Center; 2-year period.

Patients/participants: Current Procedure Terminology codes for open treatment of bimalleolar ankle and bicondylar tibial plateau fractures identified patients. Patients who had operative treatment of other injuries under the same anesthetic session were excluded. Only definitive treatment procedures were analyzed.

Intervention: We analyzed the intraoperative material costs of these procedures and compared them between surgeons. This analysis was done with a newly developed proprietary program designed for inventory and cost analysis.

Main Outcome Measurements: Mean and median total case material costs were compared using one-way analysis of variance. Individual items that significantly increased costs were identified.

Results: We identified 88 bimalleolar ankle and 46 bicondylar tibial plateau fractures treated by 6 surgeons. The mean intraoperative material cost per bimalleolar ankle fracture was $1099. The least expensive surgeon's mean case cost was $613, which was significantly less than the most expensive surgeon's $2243 (P = 0.009). The median cost range was $598-$784. The top quartile of cases resulted in 57% of overall material cost for ankle fractures. The mean intraoperative material cost per bicondylar tibial plateau fracture was $3219 (range $1839-$4088, P = 0.064). The range of median costs ($1826-$3989) was significantly wider than for ankle fractures. Bone void fillers, locking plates, adjunctive external fixators, mini-fragment locking plates, cannulated screws, single-use taps, guidewires, and drill bits all substantially increased costs.

Conclusion: This study demonstrated variation in intraoperative material cost between 6 traumatologists resulting from practice variations despite similar specialty training. The cost differences resulting from practice variation reveal potential savings through increased standardization of surgical care for similar injuries. We identified high-cost items, which could lead to cost savings if used only when they will have clinical benefit.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BOT.0000000000000687DOI Listing

Publication Analysis

Top Keywords

material cost
20
bimalleolar ankle
16
bicondylar tibial
16
tibial plateau
16
intraoperative material
16
ankle bicondylar
12
cost
11
treatment bimalleolar
8
plateau fractures
8
material costs
8

Similar Publications

Automation transformed various aspects of our human civilization, revolutionizing industries and streamlining processes. In the domain of scientific inquiry, automated approaches emerged as powerful tools, holding promise for accelerating discovery, enhancing reproducibility, and overcoming the traditional impediments to scientific progress. This article evaluates the scope of automation within scientific practice and assesses recent approaches.

View Article and Find Full Text PDF

Hierarchical Porous Aggregate-Enabled Chromatography-Inspired Single-Sensor E-Nose for Volatile Monitoring.

ACS Sens

January 2025

School of Chemistry and Molecular Engineering, In Situ Devices Research Center, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, China.

Monitoring volatile organic compounds (VOCs) is crucial for ensuring safety and health. In this study, we introduce a strategy to engineer a chromatography-inspired single-sensor (CISS) e-nose tailored for VOC monitoring. This approach overcomes the limitations of traditional methodologies and conventional e-noses.

View Article and Find Full Text PDF

As people's material living standards continue to improve, the types and quantities of household garbage they generate rapidly increase. Therefore, it is urgent to develop a reasonable and effective method for garbage classification. This is important for resource recycling and environmental improvement and contributes to the sustainable development of production and the economy.

View Article and Find Full Text PDF

Transient shear wave elastometry using a portable magnetic resonance sensor.

Magn Reson Med

January 2025

MRI Research Centre, Physics, University of New Brunswick, Fredericton, New Brunswick, Canada.

Purpose: Magnetic resonance elastography (MRE) provides detailed maps of tissue stiffness, helping to diagnose various health conditions, but requires the use of expensive clinical MRI scanners. Our approach utilizes compact, cost-effective portable MR sensors that offer bulk characterization of material properties in a region of interest close to the surface (within 1-2 cm). This accessible instrument could enable routine monitoring and prevention of diseases not readily evaluated with conventional tools.

View Article and Find Full Text PDF

Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance.

Anal Chem

January 2025

Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.

Microelectrodes offer exceptional sensitivity, rapid response, and versatility, making them ideal for real-time detection and monitoring applications. Photoelectrochemical (PEC) sensors have shown great value in many fields due to their high sensitivity, fast response, and ease of operation. Nevertheless, conventional PEC sensing relies on cumbersome external light sources and bulky electrodes, hindering its miniaturization and implantation, thereby limiting its application in real-time disease monitoring.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!