Performance of SPECT imaging systems which use a rotating gamma camera, are affected by characteristics of the detector-collimator assembly, the data acquisition method, and the filter used in image reconstruction. The purpose of this study is to examine image qualities of SPECT with different types of low energy collimators. The SPECT imaging system in this study is a rotating gamma camera ZLC-7500 (Siemens) and a data processing unit Scintipac-700 (Shimadzu). The four types of collimators compared are UHR (ultra high resolution), HR (high resolution), AP (general all purpose), and HS (high sensitivity), with 0.27, 0.66, 1.00, and 2.06 relative sensitivity, respectively. In the case of the same collimator, the spatial resolutions measured in the slice plane showed a slight difference in the FWHM values (mean values of UHR, HR, AP, and HS were 11.3 mm, 13.6 mm, 15.8 mm, and 20.4 mm, respectively.) between the center and the circumference of the field of view, in the radial direction, but a large difference in the tangential direction, with lower FWHM values (values of UHR, HR, AP, and HS were 8.4 mm, 8.7 mm, 9.3 mm, and 10.8 mm at 12 cm from the center, respectively.). In comparison of SPECT images with the four types of collimators, except for the HS collimator, image qualities of UHR, HR, and AP collimators showed only a slight difference. From the pont of view of sensitivity and spatial resolution of the collimator, it is expected that the AP collimator would be suitable for SPeCT imaging with 99mTc.

Download full-text PDF

Source
http://dx.doi.org/10.3769/radioisotopes.38.4_196DOI Listing

Publication Analysis

Top Keywords

spect imaging
12
spect images
8
rotating gamma
8
gamma camera
8
image qualities
8
types collimators
8
high resolution
8
slight difference
8
fwhm values
8
values values
8

Similar Publications

Development of Tc-Labeled Complexes with a Niraparib HYNIC Derivative for PARP-Positive Tumor Imaging.

Mol Pharm

January 2025

Key Laboratory of Radiopharmaceuticals of the Ministry of Education, NMPA Key Laboratory for Research and Evaluation of Radiopharmaceuticals (National Medical Products Administration), College of Chemistry, Beijing Normal University, Beijing 100875, P. R. China.

As an enzyme that plays an important role in DNA repair, poly(ADP-ribose) polymerase-1 (PARP-1) has become a popular target for cancer therapy. Nuclear medicine molecular imaging technology, supplemented by radiolabeled PARP-1 inhibitors, can accurately determine the expression level of PARP-1 at lesion sites to help patients choose an appropriate treatment plan. In this work, niraparib was modified with a hydrazinonicotinamide (HYNIC) group to generate the ligand NPBHYNIC, which has an affinity (IC) of 450.

View Article and Find Full Text PDF

Purpose: Parathyroid carcinoma (PC) is an extremely rare disease, typically presenting with marked elevations of serum calcium concentrations and associated with significantly increased parathyroid hormone (PTH) levels. Although it progresses slowly, approximately25% of PC patients have lung metastases. In the present study, we aimed to evaluate the role of technetium-99m methoxy isobutyl isonitrile (Tc-99m-MIBI; sestamibi) SPECT/CT scintigraphy in the preoperative localization of parathyroid adenomas, incidental metastases findings of PC, and ectopic parathyroid tissue.

View Article and Find Full Text PDF

Purpose: Monocyte chemoattractant protein-1 (MCP-1/CCL2) plays a key role for infiltration of monocytes/macrophages and studies have demonstrated that the MCP-1/C-C chemokine receptor 2 (CCR2) axis might be involved in the pathogenesis and progression of abdominal aortic aneurysms (AAA). Molecular imaging has shown potential for human clinical research studies. We evaluated the expression of CCR2 in patients with small AAA using single-photon emission computed tomography (SPECT) with the technetium-99m-6-hydrazinylnicotinoyl-C-C-chemokine receptor-2 ligand (Tc-HYNIC-CCR2-L).

View Article and Find Full Text PDF

This 2025 updated consensus outlines the diagnostic strategy for transthyretin amyloid cardiomyopathy (ATTR-CM). Given that ATTR-CM is a significant contributor to heart failure, this article emphasizes the importance of making an early and precise diagnosis, particularly as new therapeutic options become available. Highlighting the critical importance of an early and accurate diagnosis, particularly in light of emerging therapeutic modalities, this consensus underscores the central role of Tc-pyrophosphate (PYP) scintigraphy as a non-invasive diagnostic tool.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!