A technique for analyzing the composition of each voxel, in the magnetic resonance imaging (MRI) framework, is presented. By combining different acquisitions, a novel methodology, called intra voxel analysis (IVA), for the detection of multiple tissues and the estimation of their spin-spin relaxation times is proposed. The methodology exploits the sparse Bayesian learning (SBL) approach in order to solve a highly underdetermined problem imposing the solution sparsity. IVA, developed for spin echo imaging sequence, can be easily extended to any acquisition scheme. For validating the approach, simulated and real data sets are considered. Monte Carlo simulations have been implemented for evaluating the performances of IVA compared to methods existing in literature. Two clinical datasets acquired with a 3T scanner have been considered for validating the approach. With respect to other approaches presented in literature, IVA has proved to be more effective in the voxel composition analysis, in particular in the case of few acquired images. Results are interesting and very promising: IVA is expected to have a remarkable impact on the research community and on the diagnostic field.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2016.11.009DOI Listing

Publication Analysis

Top Keywords

intra voxel
8
voxel analysis
8
magnetic resonance
8
resonance imaging
8
validating approach
8
iva
5
analysis magnetic
4
imaging technique
4
technique analyzing
4
analyzing composition
4

Similar Publications

Quantitative analysis of pseudo-diffusion in diffusion-weighted magnetic resonance imaging (DWI) data shows potential for assessing fetal lung maturation and generating valuable imaging biomarkers. Yet, the clinical utility of DWI data is hindered by unavoidable fetal motion during acquisition. We present IVIM-morph, a self-supervised deep neural network model for motion-corrected quantitative analysis of DWI data using the Intra-voxel Incoherent Motion (IVIM) model.

View Article and Find Full Text PDF

Validation of a novel tool for automated tooth modelling by fusion of CBCT-derived roots with the respective IOS-derived crowns.

J Dent

December 2024

OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium; Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden. Electronic address:

Article Synopsis
  • This study aimed to validate a novel AI tool that combines dental images from two different sources, cone beam computed tomography (CBCT) and intraoral scanners (IOS), to create accurate tooth models.
  • The evaluation involved analyzing a dataset from 30 patients, calculating various accuracy metrics for the AI-generated models, and comparing them to both expert manual methods and existing segmentation approaches.
  • Results indicated that the AI-based approach achieved high accuracy similar to manual methods but was significantly faster, suggesting it could improve efficiency in dental practices.
View Article and Find Full Text PDF

The achievable spatial resolution of C metabolic images acquired with hyperpolarized C-pyruvate is worse than H images typically by an order of magnitude due to the rapidly decaying hyperpolarized signals and the low gyromagnetic ratio of C. This study is to develop and characterize a volumetric patch-based super-resolution reconstruction algorithm that enhances spatial resolution C cardiac MRI by utilizing structural information from H MRI. The reconstruction procedure comprises anatomical segmentation from high-resolution H MRI, calculation of a patch-based weight matrix, and iterative reconstruction of high-resolution multi-slice C MRI.

View Article and Find Full Text PDF

Using proton magnetic resonance spectroscopy (H MRS) to determine total creatine (tCr) concentrations will become increasingly prevalent, as the role of creatine (Cr) in supporting brain health gains interest. Methodological limitations and margins of error in repeated H MRS, which often surpass reported effects of supplementation, permeate existing literature. We examined the intra- and inter-session reliability and repeatability of H MRS for determining tCr concentrations across multiple brain regions (midbrain, visual cortex and frontal cortex).

View Article and Find Full Text PDF

Objectives: To evaluate the prevalence and predictors of ischemic lesions on thin-slice DWI (2 mm) in endovascular treatments for unruptured intracranial aneurysms (UIA), particularly explore the potential relationship with pathway plaques.

Methods: Participants eligible for endovascular treatments with UIA at a national stroke center between March 2023 and August 2023 were prospectively enrolled. All participants performed thin-slice DWI (slice thickness of 2 mm) before and after procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!