A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An Increase in Healthcare-Associated Clostridium difficile Infection Associated with Use of a Defective Peracetic Acid-Based Surface Disinfectant. | LitMetric

BACKGROUND We investigated an increase in the incidence of healthcare-associated Clostridium difficile infection (CDI) that occurred following a change from a bleach disinfectant to a peracetic acid-based disinfectant. OBJECTIVE To evaluate the efficacy of the peracetic acid-based disinfectant. DESIGN Laboratory-based product evaluation. METHODS The commercial peracetic acid-based product is activated on site by mixing a small volume of concentrated hydrogen peroxide and peracetic acid present in a "SmartCap" reservoir with the remaining contents of the container. We measured concentrations of peracetic acid in newly activated and in-use product and determined the stability of nonactivated and activated product. We tested the efficacy of the product against C. difficile spores using the American Society for Testing and Materials standard quantitative carrier disk test method. RESULTS Measured concentrations of peracetic acid (50-800 parts per million [ppm]) were significantly lower than the level stated on the product label (1,500 ppm), and similar results were obtained for containers from multiple lot numbers and from another hospital. Product with peracetic acid levels below 600 ppm had significantly reduced activity against C. difficile spores. Peracetic acid concentrations were reduced markedly after storage of either activated or nonactivated product for several weeks. The Environmental Protection Agency confirmed the finding of low disinfectant levels and ordered discontinuation of sale of the product. CONCLUSION Use of a defective peracetic acid-based surface disinfectant may have contributed to an increase in healthcare-associated CDI. Our findings highlight the importance of evaluating the efficacy of liquid disinfectants in healthcare settings. Infect Control Hosp Epidemiol 2017;38:300-305.

Download full-text PDF

Source
http://dx.doi.org/10.1017/ice.2016.275DOI Listing

Publication Analysis

Top Keywords

peracetic acid-based
20
peracetic acid
20
peracetic
10
product
9
increase healthcare-associated
8
healthcare-associated clostridium
8
clostridium difficile
8
difficile infection
8
defective peracetic
8
acid-based surface
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!