Impact of age on incidence and prevalence of moderate-to-severe cellular rejection detected by routine surveillance biopsy in pediatric heart transplantation.

J Heart Lung Transplant

Department of Pediatrics, Division of Cardiology, Washington University School of Medicine, St. Louis, Missouri, USA; Department of Pediatric Cardiology, Saint Louis Children's Hospital, St. Louis, Missouri, USA.

Published: April 2017

Background: The effect of age at transplant on rejection detected by routine surveillance biopsy (RSB) in pediatric heart transplant (HT) recipients is unknown. We hypothesized there would be low diagnostic yield and decreased prevalence of rejection detected on RSB in infants (age <1 year) when compared with children (age 1 to 9 years) and adolescents (age 10 to 18 years).

Methods: We utilized Pediatric Heart Transplant Study (PHTS) data from 2010 to 2013 to analyze moderate-to-severe (ISHLT Grade 2R/3R) cellular rejection (MSR) detected only on RSB (RSBMSR).

Results: RSB detected 280 of 343 (81.6%) episodes of MSR. RSBMSR was detected in all age groups even >5 years after HT. Infant RSBMSR had a greater proportion (p = 0.0025) occurring >5 years after HT (39.2 vs 18.4 vs 10.8%) and a lower proportion (p = 0.0009) occurring in the first year after HT (25.5 vs 60.6 vs 51.7%) compared with children and adolescents, respectively. Freedom from RSBMSR was 87 ± 7% in infants, 76 ± 6% in children and 73 ± 7% in adolescents 4 years after HT. In 1-year survivors who had RSBMSR in the first year after HT, the risk of RSBMSR occurring in Years 2 to 4 was significantly (p < 0.0001) greater than patients without RSBMSR in the first year (hazard ratio 21.28, 95% confidence interval 10.87 to 41.66), regardless of recipient age.

Conclusions: RSBMSR exists in all age groups after pediatric HT with long-term follow-up. The prevalence in infant recipients is highest >5 years after HT. Those with RSBMSR in the first year after HT are at a high risk for recurrent rejection regardless of age at HT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5426176PMC
http://dx.doi.org/10.1016/j.healun.2016.09.017DOI Listing

Publication Analysis

Top Keywords

rejection detected
12
rsbmsr year
12
detected routine
8
routine surveillance
8
surveillance biopsy
8
pediatric heart
8
occurring years
8
children adolescents
8
rsbmsr
7
years
5

Similar Publications

Highly flexible free-standing bacterial cellulose-based filter membrane with tunable wettability for high-performance water purification.

Int J Biol Macromol

December 2024

Institute of Chemicobiology and Functional Materials, School of Chemical Engineering, Nanjing University of Science and Technology, 200 Xiao Ling Wei, Nanjing 210094, China. Electronic address:

Water purification has always been a critical yet challenging issue. In this study, an organic-inorganic composite membrane was developed using 2,2,6,6-tetramethylpiperidine-1-oxyl radical (TEMPO)-oxidized bacterial cellulose (BC) nanofibers and hydroxyapatite nanowires (HAPNW) with tunable wettability for advanced membrane separation applications. The resulting free-standing TEMPO-BC/HAPNW filter membrane exhibited strong mechanical strength, high flexibility, exceptional deformability, and a high pure water flux of up to 800 L·m·h due to its porous architecture and inherent hydrophilicity.

View Article and Find Full Text PDF

Donor-derived cell-free DNA (dd-cfDNA) is an emerging non-invasive biomarker for allograft injury detection. This study aimed to evaluate a new, decentralized dd-cfDNA testing kit against a centralized dd-cfDNA testing service broadly utilized in the United States. Kidney transplant recipients with decentralized and centralized dd-cfDNA measurements and concomitant kidney allograft biopsies were included in the study.

View Article and Find Full Text PDF

Objective: We aimed to provide an evidence-supported approach to diagnose, monitor, and treat children with inflammatory bowel disease (IBD) and primary sclerosing cholangitis (PSC).

Methods: The core group formulated seven PICO-structured clinical questions. A systematic literature search from inception to December 2022 was conducted by a medical librarian using MEDLINE and EMBASE.

View Article and Find Full Text PDF

Objective: Bronchoscopy plays a critical role in the diagnosis and management of lung transplant recipients. We retrospectively evaluated the safety, complications, and efficacy of transbronchial biopsy (TBB) in detecting and grading early rejection.

Materials And Methods: We retrospectively assessed the complications associated with TBB and the adequacy of pathological diagnoses in patients who underwent lung transplantation at Koşuyolu Yüksek İhtisas Training and Research Hospital from December 1, 2016, to April 30, 2023.

View Article and Find Full Text PDF

This study proposes a novel, highly sensitive neutron detector design utilizing a unique multi-layered configuration. Each layer consists of a LiF: ZnS(Ag) scintillator coupled with a transparent neutron moderator that also functions as a light guide for the Silicon Photomultiplier (SiPM) light sensor. This design offers a cost-effective and readily available alternative for existing neutron detectors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!