A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Use of an ePTFE-covered nitinol self-expanding stent graft for the treatment off pre-closure device failure during transcatheter aortic valve replacement. | LitMetric

Objectives: Our aim was to describe our experience with the use of an ePTFE-covered nitinol self-expanding stent graft (GORE® VIABAHN® Endoprosthesis, Gore Medical, USA) placed in the common femoral artery for the treatment of suture-mediated pre-closure device failure following transcatheter aortic valve replacement (TAVR).

Background: Access site-related vascular complications (VC) following sheath removal related to pre-closure device failure during TAVR are common and treatment options may vary.

Methods: We performed an observational study on a series of consecutive patients who underwent TAVR between 2013 and 2015.

Results: Included were 25 patients at a mean (±SD) age of 82±9. Failure of the closure device resulted in overt bleeding in 19 patients, dissection or no flow in 5 patients, and angiographic pseudoaneurysm in 1. Overall 29 stents were deployed with diameters ranging from 8 to 11mm and a length of 50mm (26, 90%). All stent-graft deployments achieved complete hemostasis of the arteriotomy site and resulted in normal flow to the distal vessels. None of the patients required open surgical repair. The mean hemoglobin drop was 2.6±1.3g/dl. Blood transfusions were used in 15 (60%) patients. Acute kidney injury occurred in 4 (16%) patients, none of whom was treated with dialysis. Length of hospital stay was 9±5days. All patients survived during a 30-day follow-up period, and none had VC related to the stented site.

Conclusions: The use of an ePTFE-covered Nitinol self-expanding stent graft is a feasible, safe, and effective treatment modality for access site-related VC following TAVR.

Summary: The use of an ePTFE-covered nitinol self-expanding stent graft placed in the common femoral artery for the treatment of suture-mediated pre-closure device failure following transcatheter aortic valve replacement (TAVR) is described in 25 patients. Its use was found to be feasible, safe, and an effective treatment modality for access site-related vascular complications following TAVR.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.carrev.2016.10.006DOI Listing

Publication Analysis

Top Keywords

eptfe-covered nitinol
16
nitinol self-expanding
16
self-expanding stent
16
stent graft
16
pre-closure device
16
device failure
16
failure transcatheter
12
transcatheter aortic
12
aortic valve
12
valve replacement
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!