Objective: To compare radiation exposure during transradial diagnostic coronary angiography (DCA) using standard single- or multi-catheters with different shapes.

Background: Transradial DCA can be performed using single- or multi-catheters to canulate left and right coronary ostia. To date, it remains unknown whether there are differences in radiation exposure between the two strategies.

Methods: From November 2012 to June 2014, 3,410 consecutive patients who underwent transradial DCA were recruited. Groups were based on the initial diagnostic catheter used and were dichotomized between single- and multi-catheters approach. All crossovers were excluded. The multi-catheters approach (Multi) group consisted of Judkins left and right catheters, whereas the single-catheter (Single) group included Amplatz, Barbeau, or Multipurpose catheters. Fluoroscopy time (FT) as a surrogate end-point for total radiation exposure and kerma-area product (KAP; patient radiation exposure) were collected as radiation exposure parameters.

Results: A single-catheter strategy was used in 439 patients, while 2,971 patients had a multi-catheters approach. There was no significant difference in FT between groups (2.86 ± 1.48 min for Multi vs. 2.87 ± 1.72 min for Single, P = 0.13). The multi-catheters approach was associated with a significant 15% reduction in KAP (3,599 ± 2,214 cGy · cm vs. 3,073 ± 1,785 cGy · cm , P < 0.0001) compared to the single-catheter approach. When pooling all patients, mean FT was 2.86 ± 1.51 min. Mean KAP was 3,141 ± 1,854 cGy · cm . Reference levels in our institution in both groups were below international diagnostic reference levels. Overall both FT and KAP decreased by 15% and 19%, respectively, over the 2-year study period.

Conclusions: Compared to a single-catheter approach, a multi-catheters approach with standard Judkins catheters for DCA significantly reduced patient radiation exposure. Whether single catheter designed for DCA by radial approach can further reduce radiation exposure compared to Judkins catheters remains to be compared in randomized studies. © 2016 Wiley Periodicals, Inc.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.26851DOI Listing

Publication Analysis

Top Keywords

radiation exposure
24
multi-catheters approach
20
single- multi-catheters
16
exposure transradial
8
transradial diagnostic
8
diagnostic coronary
8
coronary angiography
8
transradial dca
8
multi-catheters
7
exposure
6

Similar Publications

Background: Robotic assistance has become increasingly prevalent in spinal surgery in recent years, emerging as a tool to increase accuracy and precision and lower complication rates and radiation exposure. The 7 and 8 Annual Seattle Science Foundation (SSF) Robotics Courses showcased presentations and demonstrations from some of the field's most experiences leaders on latest topics in robotics and spinal surgery, including cutting-edge preoperative planning technologies, augmented reality (AR) in the operating room, cervical fusion with transpedicular screws, and neuro-oncologic management. We provide a scoping review of the use of robotics technology in spinal surgery featuring highlights from the 7 and 8 Annual SSF Robotics Courses.

View Article and Find Full Text PDF

Background: Acute appendicitis is one of the most common causes of an acute abdomen among pediatric patients. The diagnosis of appendicitis is challenging due to the nonspecific presentation. Diagnosis is based on historical, physical, and serologic information as well as right lower quadrant ultrasound (RLQ US).

View Article and Find Full Text PDF

Background The thyroid gland is the most susceptible organ to radiation during the exposure of teeth because the thyroid area appears to be within the primary beam, and the dose levels are relatively high even after using collimation. This study aims to develop an eco-friendly thyroid shield by reusing lead foils from intra-oral periapical radiographic films and evaluate its effectiveness in intraoral radiography. Methods A total of 16 patients undergoing endodontic procedures who gave written consent to participate in the study were included and divided into four categories: anterior, canine, premolar, and molar.

View Article and Find Full Text PDF

Deep-UV microscopy enables high-resolution, label-free molecular imaging by leveraging biomolecular absorption properties in the UV spectrum. Recent advances in UV-imaging hardware have renewed interest in this technique for quantitative live cell imaging applications. However, UV-induced photodamage remains a concern for longitudinal dynamic imaging studies.

View Article and Find Full Text PDF

Iodine has an anti-proliferative effect on cancer cells; however, its effects have not been explored adequately. The aim of this study was to evaluate the therapeutic potential of iodine and radioiodine by assessing their effects on the viability of various breast cancer cell lines: MCF7, SKBR3, and MDA-MB231. The viability of cells was measured in treated cells exposed to six doses of iodine (5, 10, 20, 40, 60, 80 µM) and two doses of radioiodine (3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!