Background: Estimation of skeletal maturity, classically performed using Risser sign, plays a crucial role in the treatment of AIS. Recent data, however, has shown the simplified Tanner-Whitehouse (Sanders) classification, based on an anteriorposterior (AP) hand radiographs, to correlate more closely to the rapid growth phase and thus curve progression. This study evaluated the interobserver and intraobserver reliability of the Sanders and Risser classifications among clinicians at different levels of training.

Methods: Twenty AP scoliosis radiographs and 20 AP hand radiographs were randomized and distributed to 11 graders. The graders consisted of 3 orthopaedic residents, 3 spine fellows, 3 spine surgeons, and 1 radiologist. The graders were then asked to classify the radiographs according to the Sanders and Risser classifications. There were 3 rounds of grading, each done 3 weeks apart. The overall κ coefficient was then calculated for each system to evaluate the interobserver and intraobserver reliability.

Results: For all graders the average κ coefficient for the interobserver and intraobserver reliability of the Sanders classification was 0.54 and 0.62, respectively, and 0.46 and 0.49 for the Risser classification. With respect to spine attendings alone, the average κ coefficient for the interobserver and intraobserver reliability of Sanders classification was 0.72 and 0.77, respectively, and 0.46 and 0.67 for the Risser classification.

Conclusions: Our study demonstrated that the Sanders classification had moderate reliability with respect to physicians at various levels of training and had good reliability with respect to attending spine surgeons. Interestingly, the Risser staging was found to have less interobserver and intraobserver reliability overall. The Sanders classification is a reliable and reproducible system and should be in the armamentarium of surgeons who treat adolescent idiopathic scoliosis.

Level Of Evidence: Level III.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BPO.0000000000000891DOI Listing

Publication Analysis

Top Keywords

interobserver intraobserver
24
sanders classification
24
intraobserver reliability
20
reliability sanders
20
sanders
8
hand radiographs
8
sanders risser
8
risser classifications
8
spine surgeons
8
average coefficient
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!