Publications from 2011 to 2015 were selected to evaluate effect of implant surface roughness on long-term bone loss as surrogate for peri-implantitis risk. 87 out of 2,566 papers reported the mean bone loss after at least 5 years of function. Estimation of the proportion of implants with bone loss above 1, 2, and 3 mm as well as analysis the effect of implant surface roughness, smoking, and history of periodontitis was performed. By means of the provided statistical information of bone loss (mean and standard deviation) the prevalence of implants with bone loss ranging from 1 to 3 mm was estimated. The bone loss was used as a surrogate parameter for "peri-implantitis" given the fact that "peri-implantitis" prevalence was not reported in most studies or when reported, the diagnostic criteria were unclear or of dubious quality. The outcome of this review suggests that peri-implant bone loss around minimally rough implant systems was statistically significant less in comparison to the moderately rough and rough implant systems. No statistically significant difference was observed between moderately rough and rough implant systems. The studies that compared implants with comparable design and different surface roughness, showed less average peri-implant bone loss around the less rough surfaces in the meta-analysis. However, due to the heterogeneity of the papers and the multifactorial cause for bone loss, the impact of surface roughness alone seems rather limited and of minimal clinical importance. Irrespective of surface topography or implant brand, the average weighted implant survival rate was 97.3% after 5 years or more of loading. If considering 3 mm bone loss after at least 5 years to represent the presence of "peri-implantitis," less than 5% of the implants were affected. The meta-analysis indicated that periodontal history and smoking habits yielded more bone loss.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/cid.12457 | DOI Listing |
Orthop Surg
January 2025
Orthopedics Department, Gongli Hospital of Shanghai Pudong New Area, Shanghai, China.
Objective: Soft tissue defects and postoperative wound healing complications related to calcaneus fractures may result in significant morbidity. The aim of this study was to investigate whether percutaneous minimally invasive screw internal fixation (PMISIF) can change this situation in the treatment of calcaneal fractures, and aimed to explore the mechanical effects of different internal fixation methods on Sanders type III calcaneal fractures through finite element analysis.
Methods: This retrospective analysis focused on 83 patients with Sanders II and III calcaneal fractures from March 2017 to March 2022.
J Orthop Surg Res
January 2025
Department of Orthopaedics, FuyangHospital of Anhui Medical University, Fuyang, Anhui, China.
Objective: This study aims to elucidate the impact of varying tourniquet application timings on postoperative pain and the bone cement interface following TKA.
Method: Patients who underwent TKA in our department between March 2021 and July 2023 were included in this study. They were randomly assigned to three groups: Group 1 used tourniquets throughout the operation, Group 2 applied tourniquets before the osteotomy, and Group 3 applied tourniquets after completing the osteotomy.
Clin Epigenetics
January 2025
School of Biomedical Sciences and Pharmacy, The University of Newcastle, Callaghan, NSW, 2308, Australia.
Background: Hypomethylating agents (HMA), such as azacytidine (AZA) and decitabine (DAC), are epigenetic therapies used to treat some patients with acute myeloid leukaemia (AML) and myelodysplastic syndrome. HMAs act in a replication-dependent manner to remove DNA methylation from the genome. However, AML cells targeted by HMA therapy are often quiescent within the bone marrow, where oxygen levels are low.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
January 2025
Vrije Universiteit Brussel, Brussels Health Centre, Brussels, Belgium.
Purpose: Cochlear implants (CI) are the most successful bioprosthesis in medicine probably due to the tonotopic anatomy of the auditory pathway and of course the brain plasticity. Correct placement of the CI arrays, respecting the inner ear anatomy are therefore important. The ideal trajectory to insert a cochlear implant array is defined by an entrance through the round window membrane and continues as long as possible parallel to the basal turn of the cochlea.
View Article and Find Full Text PDFGeroscience
January 2025
Healthy Longevity Translational Research Program, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.
Ageing is the primary driver of age-associated chronic diseases and conditions. Asian populations have traditionally been underrepresented in studies understanding age-related diseases. Thus, the Ageing BIOmarker Study in Singaporeans (ABIOS) aims to characterise biomarkers of ageing in Singaporeans, exploring associations between molecular, physiological, and digital biomarkers of ageing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!