Purpose: The purpose of this work was to develop and evaluate a T -weighted dynamic contrast enhanced (DCE) MRI methodology where tracer-kinetic (TK) parameter maps are directly estimated from undersampled (k,t)-space data.
Theory And Methods: The proposed reconstruction involves solving a nonlinear least squares optimization problem that includes explicit use of a full forward model to convert parameter maps to (k,t)-space, utilizing the Patlak TK model. The proposed scheme is compared against an indirect method that creates intermediate images by parallel imaging and compressed sensing before to TK modeling. Thirteen fully sampled brain tumor DCE-MRI scans with 5-second temporal resolution are retrospectively undersampled at rates R = 20, 40, 60, 80, and 100 for each dynamic frame. TK maps are quantitatively compared based on root mean-squared-error (rMSE) and Bland-Altman analysis. The approach is also applied to four prospectively R = 30 undersampled whole-brain DCE-MRI data sets.
Results: In the retrospective study, the proposed method performed statistically better than indirect method at R ≥ 80 for all 13 cases. This approach provided restoration of TK parameter values with less errors in tumor regions of interest, an improvement compared to a state-of-the-art indirect method. Applied prospectively, the proposed method provided whole-brain, high-resolution TK maps with good image quality.
Conclusion: Model-based direct estimation of TK maps from k,t-space DCE-MRI data is feasible and is compatible up to 100-fold undersampling. Magn Reson Med 78:1566-1578, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5435562 | PMC |
http://dx.doi.org/10.1002/mrm.26540 | DOI Listing |
Int J Mol Sci
December 2024
Department of Biochemistry, College of Natural Sciences, Kangwon National University, Chuncheon 24341, Republic of Korea.
Recent advances in cryo-electron microscopy (cryo-EM) have facilitated the high-resolution structural determination of macromolecular complexes in their native states, providing valuable insights into their dynamic behaviors. However, insufficient understanding or experience with the cryo-EM image processing parameters can result in the loss of biological meaning. In this paper, we investigate the dihydrolipoyl acetyltransferase (E2) inner core complex of the pyruvate dehydrogenase complex (PDC) and reconstruct the 3D maps using five different symmetry parameters.
View Article and Find Full Text PDFJ Clin Med
December 2024
Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain.
: The objective of this study was to examine the trend of treatment zone (TZ) decentration over 12 months of orthokeratology (OK) wear using two Corneal Refractive Therapy (CRT) lens designs: standard (STD) and dual axis (DA). : A prospective, randomized, longitudinal study was conducted at the Optometry Clinic of the Complutense University of Madrid. Subjects were randomly fitted with an STD design or DA design in one of the eyes.
View Article and Find Full Text PDFBioengineering (Basel)
November 2024
Department of Obstetrics and Gynecology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200030, China.
Vaginal intraepithelial neoplasia (VAIN), linked to HPV infection, is a condition that is often overlooked during colposcopy, especially in the vaginal vault area, as clinicians tend to focus more on cervical lesions. This oversight can lead to missed or delayed diagnosis and treatment for patients with VAIN. Timely and accurate classification of VAIN plays a crucial role in the evaluation of vaginal lesions and the formulation of effective diagnostic approaches.
View Article and Find Full Text PDFJ Biophotonics
January 2025
School of Optoelectronics, Zhejiang University, Hangzhou, China.
The article describes a technique for digital holographic reconstruction of complex amplitude fields in diffuse blood facies using laser polarization-interference phase scanning to isolate a single scattered component of the object field. This method serves as the basis for developing algorithms for Mueller-matrix reconstruction of linear and circular birefringence parameters in the polycrystalline architectonics of blood facies. Statistical (central moments of the 1st-4th orders) and multifractal analyses (fractal dimension spectra) are applied to study the optical anisotropy maps of polycrystalline networks during blood dehydration.
View Article and Find Full Text PDFCurr Med Imaging
January 2025
Department of Radiology, The First Affiliated Hospital of Shenzhen University, Health Science Center, Shenzhen Second People's Hospital,3002 SunGangXi Road, Shenzhen, China.
Purpose: This study aims to evaluate the clinical efficacy of spectral dual-energy detector computed tomography (SDCT) and its associated parameters in diagnosing acute pulmonary embolism (APE).
Methods: Retrospective analysis of imaging data from 86 APE-diagnosed patients using SDCT was conducted. Virtual monoenergetic images (VMIs) at 40, 70, and 100 KeV, Iodine concentration (IC) maps, Electron Cloud Density Map (ECDM), Effective atomic number (Z-eff) maps, and Hounsfield unit attenuation plots (VMI slope) were reconstructed from pulmonary artery phase CT images.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!