A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cobb angle measurements on digital radiographs using Bunnell scoliometer: Validation of the method. | LitMetric

Background: Electronic rulers on computer screen are used to measure the Cobb angle (CA) instead of traditional methods with rulers, protractors and pens. The variety of software used to assess radiographs might make the CA measurements cumbersome in everyday clinical practice.

Objective: The aim of the study was to verify the method of CA measurements on digital radiographs using Bunnell scoliometer (BS).

Methods: Eighty patients with idiopathic scoliosis were enrolled into the study. CA of each curve was measured by use of Centricity software and BS. CA on 30 randomly chosen patients were measured 3 times by one researcher using only scoliometer. Three researchers measured CA on the same 30 radiographs using BS.

Results: The mean CA of 224 curves measured by Centricity and BS were 29° ± 12.2° and 28° ± 11.7°, respectively. The ICC for agreement for 2 methods was 0.96 with SEM of 1.7°. Excellent intra- and interobserver reliability of CA measurements with scoliometer was noted: ICC of 0.96 with SEM of 1.4° and ICC of 0.93 with SEM of 1.9°, respectively.

Conclusions: The study revealed excellent reliability of CA measurements on digital radiographs using the BS. The proposed method of using the Bunnell scoliometer for CA measurements may be clinically useful.

Download full-text PDF

Source
http://dx.doi.org/10.3233/BMR-150338DOI Listing

Publication Analysis

Top Keywords

measurements digital
12
digital radiographs
12
bunnell scoliometer
12
cobb angle
8
radiographs bunnell
8
measured centricity
8
096 sem
8
reliability measurements
8
measurements
6
radiographs
5