A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

SILAC-Based Quantitative Strategies for Accurate Histone Posttranslational Modification Profiling Across Multiple Biological Samples. | LitMetric

Histone posttranslational modifications (hPTMs) play a key role in regulating chromatin dynamics and fine-tuning DNA-based processes. Mass spectrometry (MS) has emerged as a versatile technology for the analysis of histones, contributing to the dissection of hPTMs, with special strength in the identification of novel marks and in the assessment of modification cross talks. Stable isotope labeling by amino acid in cell culture (SILAC), when adapted to histones, permits the accurate quantification of PTM changes among distinct functional states; however, its application has been mainly confined to actively dividing cell lines. A spike-in strategy based on SILAC can be used to overcome this limitation and profile hPTMs across multiple samples. We describe here the adaptation of SILAC to the analysis of histones, in both standard and spike-in setups. We also illustrate its coupling to an implemented "shotgun" workflow, by which heavy arginine-labeled histone peptides, produced upon Arg-C digestion, are qualitatively and quantitatively analyzed in an LC-MS/MS system that combines ultrahigh-pressure liquid chromatography (UHPLC) with new-generation Orbitrap high-resolution instrument.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-1-4939-6630-1_7DOI Listing

Publication Analysis

Top Keywords

histone posttranslational
8
analysis histones
8
silac-based quantitative
4
quantitative strategies
4
strategies accurate
4
accurate histone
4
posttranslational modification
4
modification profiling
4
profiling multiple
4
multiple biological
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!