A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Transcatheter tricuspid valve-in-valve replacement: one-year results : Alternative to surgery in high-risk patients. | LitMetric

Although rheumatic heart disease is becoming uncommon in industrialized countries, its global burden is still significant. We report the case of a 70-year-old male with rheumatic heart disease, who underwent 4 previous heart valve replacement surgeries, and presented to our hospital with refractory heart failure (NYHA functional class IV) due to severe stenosis of a previously implanted tricuspid bioprosthesis. The Heart Team deemed the patient as inoperable/high-risk for surgery. As an alternative, a transcatheter tricuspid valve-in-valve replacement was decided upon and later executed through the right femoral vein, with the insertion of an Edwards SAPIEN XT 29 no. (Edwards Lifesciences, Irvine, CA, USA) through the inferior vena cava, towards the RV, followed by direct implantation in the tricuspid bioprosthesis (valve-in-valve), under rapid pacing, without complications. A substantial clinical and echocardiographic improvement was noted after the procedure and the patient was subsequently discharged in NYHA functional class II. These favourable outcomes persisted through the 1-year follow-up period. This case report adds to the current body of evidence that tricuspid valve implantation stands as a viable and reliable alternative in the treatment of degenerated bioprosthesis in high-surgical-risk patients.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-016-0921-zDOI Listing

Publication Analysis

Top Keywords

transcatheter tricuspid
8
tricuspid valve-in-valve
8
valve-in-valve replacement
8
rheumatic heart
8
heart disease
8
nyha functional
8
functional class
8
tricuspid bioprosthesis
8
heart
5
replacement one-year
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!