Objective: To evaluate anatomical and functional outcomes after silicone oil extraction in patients with retinal detachment and proliferative vitreoretinopathy in an eye care referral center in Joinville, SC, southern Brazil.
Methods: Retrospective, noncomparative study of patients with retinal detachment and posterior proliferative vitreoretinopathy followed up after silicone oil removal. Prophylactic 360-degree peripheral laser photocoagulation was performed one to three months before silicone oil extraction. Patients with cataract underwent a combined clear corneal phacoemulsification with intraocular lens implantation in the same procedure. Anatomical outcomes were related to the duration of silicone oil tamponade and the surgical procedure performed. Functional outcomes were divided into three categories (stability, worsening, or improvement) according to visual acuity variation before the surgery and at the last follow-up visit.
Results: Fifty-three patients were followed up for a mean period of 1,262 days. Fourteen eyes (26.4%) underwent cataract surgery combined with silicone oil extraction. Forty-eight eyes (90.5%) had attached retina at the last follow-up examination. Time of intraocular tamponade and association of phacoemulsification with silicone oil extraction were not considered as risk factors for retinal redetachment. Twenty-three cases (43.4%) showed visual acuity improvement, whereas 11 cases (20.8%) were stable and 19 cases (35.8%) showed visual acuity worsening. Five patients with attached retina had unexplained optic disc atrophy.
Conclusion: Most patients had good anatomical and visual outcomes after silicone oil extraction. Prophylactic 360-degree laser retinopexy may have led to favorable outcomes. Benefits of silicone oil extraction and the associated risks of complications due to a new surgical procedure must be carefully evaluated before surgical indication.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5066514 | PMC |
http://dx.doi.org/10.1186/s40942-015-0002-y | DOI Listing |
Micromachines (Basel)
November 2024
Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan Campus, 170 Kessels Road, Brisbane, QLD 4111, Australia.
Surface wettability, the interaction between a liquid droplet and the surface it contacts, plays a key role in influencing droplet behavior and flow dynamics. There is a growing interest in designing surfaces with tailored wetting properties across diverse applications. Advanced fabrication techniques that create surfaces with unique wettability offer significant innovation potential.
View Article and Find Full Text PDFBMC Surg
January 2025
Chongqing Nanping Aier Ophthalmology, 249 Nancheng Avenue, Nanan District, Chongqing, P. R. China.
Purpose: This study aims to examine the correlation between specific clinical parameters, such as axial eye length, and the onset of ocular hypertension "OH" following the use of silicone oil filling in patients with high myopia.
Method: In this retrospective analysis, we reviewed 214 eyes from 432 patients diagnosed with severe myopia, all of whom underwent vitrectomy and were treated with silicone oil filling. The study aimed to document the incidence and timing of postoperative ocular hypertension "OH" while assessing various factors, including demographic details, medical history, additional surgical interventions, and findings from supplementary examinations (such as axial length, silicone oil emulsification, and anterior chamber penetration).
BMJ Case Rep
January 2025
LV Prasad Eye Institute Bhubaneswar Campus, MTC Campus, Bhubaneswar, India.
J Colloid Interface Sci
December 2024
Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China. Electronic address:
The depletion of lubricants in (slippery liquid-infused porous surfaces) SLIPS poses a significant challenge to their long-term functionality. While line-shaped rough structures can mitigate lubricant loss to some extent, they often fail to provide the stability required for sustained performance. In this study, we present a novel porous nanoflower aluminum alloy slippery liquid-infused surface (P-NF-AA SLIPS), which integrates a porous framework with a rough nanoflower structure.
View Article and Find Full Text PDFPLoS One
December 2024
Division of Ophthalmology, Department of Special Surgery, Faculty of Medicine, Jordan University of Science & Technology, Irbid, Jordan.
Purpose: The emulsification of silicone oil (SO) remains poorly understood. In the present study, we investigated the physical properties of unused pharmaceutical SO samples under various conditions. Moreover, clinical correlations with the patients' SO samples were assessed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!