Shear wave elastography (SWE) is a potentially valuable tool to noninvasively assess ventricular function in children with cardiac disorders, which could help in the early detection of abnormalities in muscle characteristics. Initial experiments demonstrated the potential of this technique in measuring ventricular stiffness; however, its performance remains to be validated as complicated shear wave (SW) propagation characteristics are expected to arise due to the complex non-homogenous structure of the myocardium. In this work, we investigated the (i) accuracy of different shear modulus estimation techniques (time-of-flight (TOF) method and phase velocity analysis) across myocardial thickness and (ii) effect of the ventricular geometry, surroundings, acoustic loading, and material viscoelasticity on SW physics. A generic pediatric (10-15-year old) left ventricular model was studied numerically and experimentally. For the SWE experiments, a polyvinylalcohol replicate of the cardiac geometry was fabricated and SW acquisitions were performed on different ventricular areas using varying probe orientations. Additionally, the phantom's stiffness was obtained via mechanical tests. The results of the SWE experiments revealed the following trends for stiffness estimation across the phantom's thickness: a slight stiffness overestimation for phase speed analysis and a clear stiffness underestimation for the TOF method for all acquisitions. The computational model provided valuable 3-D insights in the physical factors influencing SW patterns, especially the surroundings (water), interface force, and viscoelasticity. In conclusion, this paper presents a validation study of two commonly used shear modulus estimators for different ventricular locations and the essential role of SW modeling in understanding SW physics in the pediatric myocardium.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TUFFC.2016.2627142 | DOI Listing |
World J Stem Cells
December 2024
Kidney Disease and Transplant Center, Shonan Kamakura General Hospital, Kamakura 247-8533, Kanagawa, Japan.
Background: To date, no specific treatment has been established to reverse progressive chronic kidney disease (CKD).
Aim: To evaluate the safety and efficacy of autologous CD34 cell transplantation in CKD patients who exhibited a progressive decline in renal function.
Methods: The estimated glomerular filtration rate (eGFR) at the beginning of the study was 15.
Sci Rep
December 2024
Department of Geophysics, Graduate School of Science, Tohoku University, Sendai, 980-8578, Japan.
Accurate characterisation of seismic source mechanisms in mining environments is crucial for effective hazard mitigation, but it is complicated by the presence of anisotropic geological conditions. Neglecting anisotropic effects during moment tensor (MT) inversion introduces significant distortions in the retrieved source characteristics. In this study, we investigated the impact of ignoring anisotropy during MT inversion on the reliability of hazard assessment.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
Center for Optics Research and Engineering, State Key Laboratory of Crystal Materials, Shandong University, Qingdao 266237, China.
Shear mode ultrasonic waves are in high demand for structural health monitoring (SHM) applications owing to their nondispersive characteristics, singular mode, and minimal energy loss, especially in harsh environments. However, the generation and detection of a pure shear wave using conventional piezoelectric materials present substantial challenges because of their complex piezoelectric response, involving multiple modes. Herein, we introduce a high-quality piezoelectric crystal BiSiO (BSO), exhibiting a robust piezoelectric response ( = 45.
View Article and Find Full Text PDFAnn Med
December 2025
Department of Ultrasonographl, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, Shanxi Province, China.
Objective: To explore the differences of conventional ultrasound characteristics, elastic imaging parameters and clinicopathological characteristics of distinct molecular subtypes of breast cancer in young women, and to identify imaging parameters that exhibited significant associations with each molecular subtype.
Methods: We performed a retrospective analysis encompassing 310 young women with breast cancer. Observations were made regarding the ultrasonography and elastography characteristics of the identified breast lesions.
BMC Med Imaging
December 2024
Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, China.
Objective: This study explored the value of stomach ultrasound reporting and data system (Su-RADS) and two-dimensional shear wave elastography (2D-SWE) in the diagnosis of benign and malignant lesions of the gastric wall, evaluating the feasibility of combining the two methods for the diagnosis of gastric wall lesions.
Methods: 113 patients with gastric wall lesions were examined after oral gastric ultrasound contrast agent, and the grades of the gastric wall lesions were classified according to Su-RADS. Moreover, 2D-SWE was performed to measure the E value of the lesions.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!