Background: Graft fixation is critical to the restoration of the medial patella of femoral ligament function and long-term success. Numerous fixations at the patella have been described, while the complications including patellar fractures, violation of the posterior patella and delay of tendon-to-bone healing remain significant challenges. Here, we describe a safe and firm fixation at the patellar for medial patellofemoral ligament (MPFL) reconstruction and explore the safety angle of drilling the suture anchor at different morphology of the patellar. Moreover, we evaluate the results at a 3-year follow-up.
Methods: Combined bone groove and suture anchor fixation at the patella was performed on 26 patients (16 females, 10 males; mean age 26.3 ± 4.7 years) diagnosed with recurrent patellar dislocation. The drilling direction of the suture anchor referred to the safety angle according to the Wiberg type classification. The safety angle was defined as the angle between the drill tunnel and a line that connected the medial and lateral margins of the patella and was established following computed tomography assessment of 117 patients who were diagnosed with patellar dislocation in our hospital according to the Wiberg type classification (I:29, II:65, III:23). X-ray, Lysholm, Kujala and Tegner scores were obtained preoperatively and at the time of final follow-up.
Results: There were no patellar complications, including fracture and redislocation. Average congruence, patella tilt angles and lateral patella angle were significantly changed (P < 0.01). The Lysholm, Kujala and Tegner scores were significantly increased (P < 0.01). The safe angles of male and female patients according to the patellar Wiberg type classification were less than 45.32 ± 1.76 and 41.20 ± 1.33, 69.74 ± 1.38 and 63.66 ± 1.45 and 84.11 ± 1.67 and 80.26 ± 1.73, respectively.
Conclusions: We achieved encouraging results with this fixation at the patellar. When drilling from Wiberg type I to type III patellar, the suture anchor should be more vertical. When fixing the patellar of female patients, the drilling suture anchor should be more sloping.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5109655 | PMC |
http://dx.doi.org/10.1186/s13018-016-0473-z | DOI Listing |
BMC Surg
January 2025
Department of Hand and Foot Surgery, Shandong Provincial Hospital, Shandong First Medical University, Jinan, China.
The deltoid ligament (medial collateral ligament) and the syndesmosis (a composite ligamentous structure at the distal tibiofibular junction) are critical for maintaining ankle stability. In cases of high-energy ankle fractures, these structures are often injured simultaneously, leading to instability and potential long-term complications such as post-traumatic arthritis. This review aims to explore advancements in minimally invasive techniques for the treatment of combined deltoid ligament and syndesmosis injuries, with a focus on optimizing surgical outcomes and reducing patient morbidity.
View Article and Find Full Text PDFThis prospective, observational cohort study compares the clinical and radiographic outcomes of the modified Weaver and Dunn (WD) technique with the newer, anatomical double-button plus tendon allograft technique (DB), and the suture anchor repair plus tendon allograft (SA). The study cohort includes 53 patients, who underwent surgery for acromioclavicular joint (ACJ) dislocation Rockwood type 3, 4 and 5. Patient-reported outcome scores and clinical results, including Disabilities of the Arm, Shoulder and Hand (DASH), the Subjective Shoulder Value (SSV), the Visual Analogue Scale (VAS) and the Constant score (CS) results as well as loss of reduction rates on plain radiographs were compared.
View Article and Find Full Text PDFPak J Med Sci
January 2025
Zhenfeng Huang Department of Orthopedic Trauma, Wuhan Fourth Hospital, Wuhan, Hubei Province 430000, P.R. China.
Objective: To explore the therapeutic effect of titanium locking plate combined with suture anchor (SA) repair in the treatment of proximal humeral fractures (PHF).
Methods: This retrospective study was conducted by analyzing the clinical data of 113 patients with PHF admitted to Wuhan Fourth Hospital from March 2021 to October 2023. Among them, 55 patients underwent open reduction and internal fixation (OR/IF) using titanium locking plate (OR/IF group), and 58 patients underwent surgery with titanium locking plate combined with SA (SA group).
PeerJ
January 2025
College of Engineering, University of Tennessee - Knoxville, TN, United States of America.
Objective: The purpose of this study was to investigate the timing and mode of failure of metallic screw-type suture anchors used to attach artificial tendons to bone in an New Zealand White rabbit model.
Study Design: Metal suture anchors with braided composite sutures of varying sizes (United States Pharmacopeia (USP) size 1, 2, or 5) were used to secure artificial tendons replacing both the Achilles and tibialis cranialis tendons in 12 female New Zealand White rabbits. Artificial tendons were implanted either at the time of (immediate replacement, = 8), or four/five weeks after (delayed replacement, = 4) resection of the biological tendon.
Arch Orthop Trauma Surg
January 2025
Training Center for Emergency Medicine (NOTIS E.V), Engen, Germany.
Introduction: More extensive and cohesive studies on quadriceps tendon rupture (QTR) repair surgery are required to guide effective treatment strategies. Therefore, in this study, we aimed to identify predictors of subjective functional recovery following QTR repair surgery.
Materials And Methods: This multicentre retrospective cohort study enrolled 191 adults (age ≥ 18 years) who underwent surgical unilateral QTR repair (2010-2022) and had ≥ 1-year postoperative follow-up at three trauma centres in Germany.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!