Helium, sulfur hexafluoride-oxygen, and air were modeled to examine the role of the gas density on the pendelluft-induced lung injury (PILI) under high frequency oscillatory ventilation (HFOV). Large eddy simulation coupled with physiological resistance-compliance boundary conditions was applied to capture pendelluft-induced gas entrapment and mechanical stresses in an image-based human lung model. The flow characteristics were strongly dependent on the inspired gas density. The flow partitioning, globally between the left and right lung and locally between adjacent units branches, was significantly affected by the density of inhaled gas and was more balanced when inspiring lighter gas. The incomplete loops of flow-volume and volume-pressure curves were significantly influenced by the variations of the flow redistribution, resistance, and turbulence associated with the pendelluft mechanism. Inhaling light gas reduced the entrapped gas volume and mechanical stress surrounding carina ridges signifying the important role of inhaled gas properties on PILI. In general, lung ventilation by HFOV with a gas mixture of large amounts of Helium is thought to mitigate ventilator complications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2016.10.041 | DOI Listing |
Anesthesiology
January 2025
Department of Critical Care, Melbourne Medicine School, Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Victoria, Australia.
Background: Multi-compartment computer models of heterogeneity in alveolar ventilation-perfusion ratios (VA/Q scatter) across the lung explain the significant alveolar-arterial (A-a) partial pressure gradients and associated alveolar dead-space fractions (VDA/VA) seen in anesthetized patients for both carbon dioxide and for anesthetic gases of different blood solubilities. However, the accuracy of a simpler two-compartment model of VA/Q scatter to do this has not been tested or compared to calculations from the traditional Riley model with "ideal", unventilated (shunt) and unperfused (deadspace) compartments.
Methods: Measurements of gas partial pressures in inspired and expired gas and arterial and mixed venous blood from 29 patients undergoing inhalational general anesthesia for cardiac surgery was used to compare the accuracy of two simple models of VA/Q scatter and lung gas exchange in predicting measured alveolar and arterial partial pressure differences, and associated alveolar dead-space calculations for the modern anesthetic gases isoflurane, sevoflurane and desflurane.
Integr Environ Assess Manag
January 2025
Department of Environmental Health Engineering, Faculty of Health, Shiraz University of Medical Sciences, Shiraz, Iran.
This study aimed to evaluate the concentrations of sulfur dioxide (SO2) and nitrogen oxides (NOX) around the Qom (a province in Iran) combined cycle power plant in relation to seasonal variations and fuel type from December 2014 to May 2015. Passive sampling was used in three monitoring sites around the power plant to assess noncarcinogenic health risks associated with exposure to SO2 and NOX. Results showed the higher concentrations of NOX and SO2 in winter than in spring.
View Article and Find Full Text PDFERJ Open Res
January 2025
Interstitial Lung Diseases Unit, Bellvitge University Hospital, Bellvitge Biomedical Research Institute (IDIBELL), CIBERES, Barcelona, Spain.
Autoimmune pulmonary alveolar proteinosis (aPAP), which accounts for >90% of all cases of PAP, is a rare lung disease mediated by granulocyte-macrophage colony-stimulating factor (GM-CSF) autoantibodies that block GM-CSF signalling, leading to reduced surfactant clearance causing abnormal accumulation of alveolar surfactant and impaired gas exchange [1-3]. The current standard of care for aPAP is whole-lung lavage (WLL), which is invasive, resource intensive, carries procedural risk, does not address the underlying cause of disease and often must be repeated regularly [4]. Hence, there is a therapeutical need to address the underlying pathophysiology of the disease.
View Article and Find Full Text PDFEnviron Int
January 2025
Department of Environmental Health Sciences, Graduate School of Public Health, Seoul National University, Seoul, Republic of Korea; Institute of Health and Environment, Seoul National University, Seoul, Republic of Korea. Electronic address:
This study evaluated the inhalation of mask-derived materials by simulating real breathing conditions and examined how the amount of inhaled materials varies with breathing flow rate and duration. Three types of non-certified reusable masks and two types of certified disposable masks were selected. For each mask, five different hazardous materials were captured and analyzed in three replicates with two breathing flow rates of 30 L/min and 85 L/min and two breathing time combinations of 15 min and 60 min.
View Article and Find Full Text PDFJ Clin Anesth
January 2025
Department of Anesthesiology, Pain Management, & Perioperative Medicine, Henry Ford Health, Detroit, MI, USA. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!