A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantifying the Ponseti method. | LitMetric

Quantifying the Ponseti method.

J Mech Behav Biomed Mater

Department of Biomechanical Engineering, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands; Department of Rehabilitation Medicine, University of Groningen, University Medical Center Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands.

Published: February 2017

The Ponseti method is the accepted treatment of idiopathic clubfoot. Although the method of manipulating the baby feet is described in great detail, current study aimed to investigate the magnitude and course of the applied forces in order to optimise the treatment of clubfoot. An instrumented clubfoot model was constructed with force sensors on the location of the first metatarsal (FM) and the talar neck (TN) and treated with the Ponseti method by 17 practitioners. Applied forces on FM and TN were measured during manipulation (4.2N; 12N), during casting (3.2N; 3.5N) and after casting (2.9N; 2.2N). The forces during manipulation were significantly higher than during casting on TN (p<0.001) but not on FM (p=0.129). No 'correct' amount of force could be determined and inter-practitioner variability was measured to be 70%. The resulting pressure of the cast on the clubfoot model as measured directly after casting was significantly higher than local tissue perfusion. The results of this study suggest potential for the optimisation of the application of the Ponseti method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2016.10.021DOI Listing

Publication Analysis

Top Keywords

ponseti method
12
applied forces
8
quantifying ponseti
4
method
4
method ponseti
4
method accepted
4
accepted treatment
4
treatment idiopathic
4
idiopathic clubfoot
4
clubfoot method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!