A wide variety of medical devices (MDs) used in hospitals are made of flexible plasticized polyvinylchloride (PVC). Different plasticizers are present in variable amounts in the PVC matrix of the devices and can leach out into the infused solutions and may enter into contact with the patients. The ARMED project aims to assess the migration of these plasticizers from medical devices and therefore the level of exposure in patients. For the first task of the project, eight methods were developed to directly detect and quantify the plasticizers in the PVC matrix of the MDs. We compared the overall performances of the analytical methods using standardized and validated criteria in order to provide the scientific community with the guidance and the technical specifications of each method for the intended application. We have shown that routine rapid screening could be performed directly on the MDs using the FTIR technique, with cost-effective analyses. LC techniques may also be used, but with limits and only with individual quantification of the main plasticizers expected in the PVC matrix. GC techniques, especially GC-MS, are both more specific and more sensitive than other techniques. NMR is a robust and specific technique to precisely discriminate all plasticizers in a MD but is limited by its cost and its low ability to detect and quantify plasticizer contamination, e.g. by DEHP. All these results have been confirmed by a real test, called the " blind test " carried out on 10 MD samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2016.10.033 | DOI Listing |
Nat Cell Biol
January 2025
Department of Cell Biology and Physiology, Washington University School of Medicine, St. Louis, MO, USA.
Mitochondria are central to myriad biochemical processes, and thus even their moderate impairment could have drastic cellular consequences if not rectified. Here, to explore cellular strategies for surmounting mitochondrial stress, we conducted a series of chemical and genetic perturbations to Saccharomyces cerevisiae and analysed the cellular responses using deep multiomic mass spectrometry profiling. We discovered that mobilization of lipid droplet triacylglycerol stores was necessary for strains to mount a successful recovery response.
View Article and Find Full Text PDFAAPS PharmSciTech
January 2025
Department of Pharmaceutical Sciences and Technology, Maharaja Ranjit Singh Punjab Technical University (MRSPTU), Bathinda, 151001, Punjab, India.
Microneedles (MNs) appear as a transformative and minimally invasive platform for transdermal drug delivery, representing a highly promising strategy in wound healing therapeutics. This technology, entailing the fabrication of micron-scale needle arrays, enables the targeted and efficient delivery of bioactive agents into the epidermal and dermal layers without inducing significant pain or discomfort. The precise penetration of MNs facilitates localized and sustained drug release, which significantly enhances tissue regeneration and accelerates wound closure.
View Article and Find Full Text PDFInt J Implant Dent
January 2025
School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, 310053, People's Republic of China.
Purpose: SLM 3D printing technology is one of the most widely used implant-making technologies. However, the surfaces of the implants are relatively rough, and bacteria can easily adhere to them; increasing the risk of postoperative infection. Therefore, we prepared a near-infrared photoresponsive nano-TiO coating on the surface of an SLM 3D-printed titanium alloy sheet (Ti6Al4V) via a hydrothermal method to evaluate its antibacterial properties and biocompatibility.
View Article and Find Full Text PDFWorld J Microbiol Biotechnol
January 2025
The Biotechnology Center, Faculty of Pharmacy, Cairo University, Cairo, 11562, Egypt.
This study reports the isolation and characterization of highly resistant bacterial and microalgal strains from an Egyptian wastewater treatment station to cyanide-containing compounds. The bacterial strain was identified as Bacillus licheniformis by 16S rRNA gene sequencing. The isolate removed up to 1 g L potassium cyanide, 3 g L benzonitrile, and 1 g L sodium salicylate when incubated as 10% v/v in MSM at 30 ℃.
View Article and Find Full Text PDFMikrochim Acta
January 2025
Federal University of Uberlândia, Chemistry Institute, Uberlândia, MG, 38400-902, Brazil.
The use of 3D-printed electrodes is reported fabricated from in-house conductive filament composed of a mixture of recycled poly (lactic acid) (rPLA), graphite (Gpt), and carbon black (CB) for fast detection of the abused drug ketamine. Firstly, the performance of these electrodes was evaluated in comparison to 3D-printed electrodes produced employing a commercially available conductive filament. After a simple pretreatment step (mechanical polishing), the new 3D-printed electrodes presented better performance than the electrodes produced from commercial filament in relation to peak-to-peak separation of the redox probe [Fe(CN)]/ (130 mV and 759 mV, respectively), charge transfer resistance (R = 1.