Contactless microparticle control via ultrahigh frequency needle type single beam acoustic tweezers.

Appl Phys Lett

NIH Resource Center for Medical Ultrasonic Transducer Technology and Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90089, USA.

Published: October 2016

This paper reports on contactless microparticle manipulation including single-particle controlled trapping, transportation, and patterning via single beam acoustic radiation forces. As the core component of single beam acoustic tweezers, a needle type ultrasonic transducer was designed and fabricated with center frequency higher than 300 MHz and -6 dB fractional bandwidth as large as 64%. The transducer was built for an -number close to 1.0, and the desired focal depth was achieved by press-focusing technology. Its lateral resolution was measured to be better than 6.7 m by scanning a 4 m tungsten wire target. Tightly focused acoustic beam produced by the transducer was shown to be capable of manipulating individual microspheres as small as 3 m. "USC" patterning with 15 m microspheres was demonstrated without affecting nearby microspheres. These promising results may expand the applications in biomedical and biophysical research of single beam acoustic tweezers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5085970PMC
http://dx.doi.org/10.1063/1.4966285DOI Listing

Publication Analysis

Top Keywords

single beam
16
beam acoustic
16
acoustic tweezers
12
contactless microparticle
8
needle type
8
beam
5
acoustic
5
microparticle control
4
control ultrahigh
4
ultrahigh frequency
4

Similar Publications

Article Synopsis
  • The study aimed to create a predictive model for late rectal bleeding in prostate cancer patients undergoing different types of radiotherapy.
  • Candidate predictors were identified from prior research and five logistic regression models were tested based on various dose parameters.
  • Results indicated that certain dosimetric predictors and history of abdominal surgery were significant for predicting the outcome, with some models showing satisfactory internal validation, but external validation is necessary for confirmation.
View Article and Find Full Text PDF

Objectives: Radiotherapy manages pancreatic cancer in various settings; however, the proximity of gastrointestinal (GI) luminal organs-at-risk (OAR) poses challenges to conventional radiotherapy. Proton beam therapy (PBT) may reduce toxicities compared to photon therapy. This consensus statement summarizes PBT's safe and optimal delivery for pancreatic tumors.

View Article and Find Full Text PDF

Development and evaluation of an in-beam PET system for proton therapy monitoring.

Phys Med Biol

January 2025

The Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei 430074, Wuhan, Hubei, 430074, CHINA.

Objective: In-beam positron emission tomography (PET) has important development prospects in real-time monitoring of proton therapy. However, in the beam-on operation, the high bursts of radiation events pose challenges to the performance of the PET system.

Approach: In this study, we developed a dual-head in-beam PET system for proton therapy monitoring and evaluated its performance.

View Article and Find Full Text PDF

Study on a Strategy to Improve the Image Quality and Imaging Depth for Novel Synthetic Aperture Schemes: An Experimental Investigation.

Ultrason Imaging

January 2025

Biomedical Ultrasound Imaging Laboratory, Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology, Madras, Chennai, India.

Imaging depth remains a restriction for Synthetic Aperture (SA) approaches, even though SA techniques have been shown to overcome some of the drawbacks of Conventional Focused Beamforming (CFB) technique. This limitation is attributed to lesser energy per transmit in SA techniques compared to that of CFB technique. Therefore, in this paper, a systematic investigation is done to evaluate the improvement in imaging depth and image quality of B-mode ultrasound images in the case of SA technique using PZT transducer by boosting the input voltage to the transducer, while measuring the acoustic exposure parameters recommended in international standards.

View Article and Find Full Text PDF
Article Synopsis
  • Dynamic conformal arc therapy (DCAT) and volumetric modulated arc therapy (VMAT) both provide similar quality for treating brain metastases, but this study focused on how MLC errors during treatment affect dose distribution.
  • Researchers created reference plans and simulated MLC errors using a head phantom, analyzing how these errors influenced dose delivery to the targets and surrounding brain tissue.
  • The findings revealed that while MLC errors affected both techniques' dose distribution similarly, the DCAT technique showed greater resilience, with less variation in target doses compared to VMAT.
View Article and Find Full Text PDF