To computationally optimize the design of an endovascular magnetic filtration device that binds iron oxide nanoparticles and to validate simulations with experimental results of prototype devices in physiologic flow testing. Three-dimensional computational models of different endovascular magnetic filter devices assessed magnetic particle capture. We simulated a series of cylindrical neodymium N52 magnets and capture of 1500 iron oxide nanoparticles infused in a simulated 14 mm-diameter vessel. Device parameters varied included: magnetization orientation (across the diameter, "D", along the length, "L", of the filter), magnet outer diameter (3, 4, 5 mm), magnet length (5, 10 mm), and spacing between magnets (1, 3 mm). Top designs were tested in vitro using Zr-radiolabeled iron oxide nanoparticles and gamma counting both in continuous and multiple pass flow model. Computationally, "D" magnetized devices had greater capture than "L" magnetized devices. Increasing outer diameter of magnets increased particle capture as follows: "D" designs, 3 mm: 12.8-13.6 %, 4 mm: 16.6-17.6 %, 5 mm: 21.8-24.6 %; "L" designs, 3 mm: 5.6-10 %, 4 mm: 9.4-15.8 %, 5 mm: 14.8-21.2 %. In vitro, while there was significant capture by all device designs, with most capturing 87-93 % within the first two minutes, compared to control non-magnetic devices, there was no significant difference in particle capture with the parameters varied. The computational study predicts that endovascular magnetic filters demonstrate maximum particle capture with "D" magnetization. In vitro flow testing demonstrated no difference in capture with varied parameters. Clinically, "D" magnetized devices would be most practical, sized as large as possible without causing intravascular flow obstruction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5468174PMC
http://dx.doi.org/10.1007/s10544-016-0135-2DOI Listing

Publication Analysis

Top Keywords

endovascular magnetic
16
particle capture
16
iron oxide
12
oxide nanoparticles
12
magnetized devices
12
capture
9
magnetic filter
8
flow testing
8
parameters varied
8
outer diameter
8

Similar Publications

This study aims to develop and validate a standardized methodology for creating high-fidelity, custom-made, patient-specific 3D-printed vascular models that serve as tools for preoperative planning and training in the endovascular treatment of peripheral artery disease (PAD). Ten custom-made 3D-printed vascular models were produced using computed tomography angiography (CTA) scans of ten patients diagnosed with PAD. CTA images were analyzed using Syngo.

View Article and Find Full Text PDF

Thoracic vertebral body erosion due to a perianeurysmal outpouching lesion after thoracic endovascular aortic repair: a case report and literature review.

BMC Musculoskelet Disord

January 2025

Spine Center and Department of Orthopedic Surgery, Inje University Sanggye Paik Hospital, College of Medicine, Inje University, 1342, Dongil-Ro, Seoul, Nowon-Gu, 01757, Republic of Korea.

Background: The safety of endovascular treatment, such as thoracic endovascular aortic repair (TEVAR), for a descending thoracic aortic aneurysm has been well-established, with a reported low postoperative mortality rate but higher incidences of long-term complications such as endo-leakage, device failure, and aneurysm-related death. Based on this, we report the first case of massive thoracic vertebral body erosion due to a perianeurysmal outpouching lesion after TEVAR.

Case Presentation: A 77-year-old female with a history of TEVAR due to descending thoracic aortic arch aneurysm 4 years ago was referred from the cardiovascular clinic to the spine center.

View Article and Find Full Text PDF

Background: Mechanical thrombectomy (MT) is the standard of care for eligible acute ischemic stroke (AIS) patients with large vessel occlusion (LVO) since 2015.

Aim: Our aim was to determine the key challenges for MT implementation and access worldwide.

Methods: We conducted an international online survey consisting of 37 questions, distributed through the World Stroke Organization network, and as invited by co-authors between December 2022 and March 2023.

View Article and Find Full Text PDF

An adult patient was admitted to our emergency department for a first episode of generalized tonic-clonic seizure. Computed tomography scan and magnetic resonance imaging showed a temporal intracranial hemorrhage and parenchymal edema caused by a dural arteriovenous fistula (DAVF), whose angioarchitecture was better understood through the DSA which showed as intriguing and rare vascular anomaly the origin of the posterior inferior cerebellar artery (PICA) from the middle meningeal artery (MMA). The endovascular treatment of the DAVF was then successfully performed.

View Article and Find Full Text PDF

Traumatic direct type carotid cavernous fistula (CCF) is an acquired arteriovenous shunt between the carotid artery and the cavernous sinus post severe craniofacial trauma or iatrogenic injury. We reported a 46-year-old woman who had developed a traumatic direct type CCF after severe head trauma with a skull base fracture and brain contusion hemorrhage. The clinical manifestations of the patient included pulsatile exophthalmos, proptosis, bruits, chemosis, and a decline in consciousness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!