AI Article Synopsis

  • Alzheimer's disease (AD) can start developing up to 20 years before symptoms appear, making early diagnosis critical, with glycated albumin identified as a potential biomarker for AD.
  • An electrochemical biosensor was developed to directly measure glycated albumin, utilizing a copper complex on a gold electrode and RAGE domains for recognition, with detection monitored through voltammetry.
  • The biosensor demonstrated high selectivity and sensitivity for glycated albumin, with detection limits in the picomolar range, suggesting it could be an effective tool for analyzing medical samples related to AD.

Article Abstract

Background: Alzheimer's disease (AD) is the most common form of dementia. The process of AD can begin 20 years before any symptom of cognitive loss. Thus, the development of systems for early diagnosis and prevention is very important. The mechanism of AD is still under debate. Nevertheless, higher levels of glycated albumin in cerebrospinal fluid and plasma are observed in AD patients. Therefore, glycated albumin could be a biomarker of AD development.

Methods: Electrochemical biosensor for direct determination of glycated albumin was based on thiol derivative of pentetic acid (DTPA) complex with Cu(II) created on gold electrode surface. His-tagged domains of Receptors for Advanced Glycation End Products (RAGE) were applied as analytical active element for glycated albumin recognition. The binding of glycated albumin by His6- RAGE domains was monitored using Osteryoung square - wave voltammetry.

Results: Electrodes modified with His6 - RAGE VC1 natural domain generated decrease of Cu(II) redox currents in the presence of glycated albumin. Human albumin, Aβ 1-40 and S100B protein caused negligible influence on biosensors responses towards glycated albumin. The detection limits were: 2.3 pM, 1.1 pM, 2.9 pM and 3.1 pM in the presence of: buffer, buffer + albumin, buffer + S100B, buffer + Aβ1-40 , respectively.

Conclusion: The presented electrochemical biosensor was successfully applied for the determination of glycated albumin. Considering analytical parameters such as good selectivity and sensitivity in pM range, biosensor could be recommended as an analytical tool for medical samples analysis.

Download full-text PDF

Source
http://dx.doi.org/10.2174/1567205013666161108110542DOI Listing

Publication Analysis

Top Keywords

glycated albumin
36
electrochemical biosensor
12
albumin
11
glycated
9
determination glycated
8
biosensor detection
4
detection glycated
4
albumin background
4
background alzheimer's
4
alzheimer's disease
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!