A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Screw-type device diameter and orthodontic loading influence adjacent bone remodeling. | LitMetric

Objective: To evaluate the effect of diameter and orthodontic loading of a screw-type implantable device on bone remodeling.

Materials And Methods: Screw-shaped devices of four distinct diameters, 1.6, 2, 3, and 3.75 mm, were placed into edentulous sites in five skeletally mature beagle dogs (n = 14/dog) following premolar extraction. Using a split-mouth design, devices on one side were loaded using calibrated 2N coil springs. Epifluorescent bone labels were administered intravenous prior to sacrifice. Bone-implant sections (∼ 70 μm) were evaluated to quantify bone formation rate (BFR), and other histomorphometric variables were assessed in the implant supporting bone.

Results: The mean BFR ranged from 10.93 percent per year to 38.91 percent per year. BFR in the bone adjacent to the device was lower for the loaded 1.6-mm screws when compared with the nonloaded 1.6-mm screws (P < .01) and the loaded 2.0-, 3.0-, and 3.75-mm diameter screws (P < .01). No significant differences in BFR were noted, regardless of loading condition, between the 2.0-, 3.0-, and 3.75-mm diameter screws.

Conclusions: We detected a dramatic reduction in bone remodeling. Although orthodontic loading of 2N did not alter bone remodeling associated with screws with a 2.0-mm diameter or larger, it did decrease bone remodeling adjacent to a loaded 1.6-mm screw. The long-term effect of this diminished remodeling should be further investigated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8381998PMC
http://dx.doi.org/10.2319/041316-302.1DOI Listing

Publication Analysis

Top Keywords

bone remodeling
16
orthodontic loading
12
diameter orthodontic
8
bone
8
percent year
8
loaded 16-mm
8
16-mm screws
8
20- 30-
8
30- 375-mm
8
375-mm diameter
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!