Conservative hip implants preserve healthy bone for revision surgeries and improve physiological loading; however, they have little supporting biomechanical data with respect to their 3D orientation during implantation. This study endeavored to determine the optimal 3D orientation of a straight short stem hip implant within the proximal femur that would yield a stress distribution most similar to an intact femur. Synthetic femurs were implanted with a stem in one of seven maximum angles or positions and axially loaded, with resultant strain values used to validate a finite element model. Design of experiments was used to analyze the range of potential implant orientations under three gait cycle loading conditions. A global optimal orientation of 9.14° valgus, 2.49° anteversion, 0.48mm posterior position, and 0.23mm inferior position was found to yield stress distributions most similar to the intact femur across the gait cycle range. In general, it was determined that the valgus orientation was optimal throughout the gait cycle, consistently exhibiting a stress distribution more similar to that of the intact femur. Minimal levels of anterior/posterior and inferior positioning were seen to be beneficial in achieving more physiological stresses in specific regions of interest within the proximal femur, while the anteverted orientation was only beneficial in loading under flexion. Overall, orthopaedic surgeons should aim to implant straight short stem hip implants in valgus up to 10°, with an otherwise neutral position and version, unless some degree of deviation would be beneficial for a patient-specific reason. This work has implications for the best surgical placement of straight short stem hip implants to yield maximal biomechanical stability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.medengphy.2016.10.002 | DOI Listing |
Commun Med (Lond)
January 2025
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30322, USA.
Background: Adolescent idiopathic scoliosis (AIS) is the most common type of scoliosis, affecting 1-4% of adolescents. The Scoliosis Research Society-22R (SRS-22R), a health-related quality-of-life instrument for AIS, has allowed orthopedists to measure subjective patient outcomes before and after corrective surgery beyond objective radiographic measurements. However, research has revealed that there is no significant correlation between the correction rate in major radiographic parameters and improvements in patient-reported outcomes (PROs), making it difficult to incorporate PROs into personalized surgical planning.
View Article and Find Full Text PDFNeuroimage
December 2024
INSERM U1114, Cognitive Neuropsychology and Pathophysiology of Schizophrenia, 1 place de l'Hôpital, 67091 Strasbourg Cedex, France; INSERM U1329, team Psychiatry of STEP (Strasbourg Translational nEuroscience and Psychiatry), 1 place de l'Hôpital, 67091 Strasbourg Cedex, France. Electronic address:
Time prediction is pervasive, and it is unclear whether it is supra-modal or task-specific. This study aimed to investigate the role of motor temporal prediction in preparing to stop a movement following a sensory stimulus. Participants performed a straight-line movement with their finger until a target signal, which occurred after a short or long foreperiod.
View Article and Find Full Text PDFACS Appl Nano Mater
December 2024
Mechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.
The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored.
View Article and Find Full Text PDFMaterials (Basel)
November 2024
Department of Mechanics, Mathematics and Management, Politecnico di Bari University, 70125 Bari, Italy.
The aim of this finite element analysis (FEA) was to investigate the distribution of von Mises stress within dental implant components, as well as trabecular and cortical bone. The study considered various bone qualities that influence cortical thickness in contact with the implant, specifically examining cortical thicknesses of 0.5, 1.
View Article and Find Full Text PDFAdv Mater
December 2024
Department of Materials Science and Engineering, Drexel University, Philadelphia, PA, 19104, USA.
An innovative process to multifunctional vitrimer nanocomposites with a percolative MXene minor phase is reported, marking a significant advancement in creating stimuli-repairable, reinforced, sustainable, and conductive nanocomposites at diminished loadings. This achievement arises from a Voronoi-inspired biphasic morphological design via a straight-forward three-step process involving ambient-condition precipitation polymerization of micron-sized prepolymer powders, aqueous powder-coating with 2D MXene (TiCT), and melt-pressing of MXene-coated powders into crosslinked films. Due to the formation of MXene-rich boundaries between thiourethane vitrimer domains in a pervasive low-volume fraction conductive network, a low percolation threshold (≈0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!