Demographic data point to a substantial proportion of women in the population of elderly patients with an increasing prevalence of aortic stenosis. Implantation of an aortic bioprosthesis via an endovascular approach known as Transcatheter aortic valve implantation (TAVI) in patients presenting with a symptomatic tight aortic stenosis (severe aortic stenosis) (AS) is an alternative therapeutic option to surgical aortic valve replacement in patients at high surgical risk or ineligible for surgery. The literature has shown that this technique seems to be particularly beneficial in female patients. In the Partner A trial, the 1-year mortality rate was significantly lower in women compared to their male counterparts. Other data revealed that although women have a higher risk of experiencing periprocedural complications (vascular events, bleeding and stroke), their outcome is good and often better than that of men. These results are continuously improving thanks to the enhancement of techniques and devices. In view of the published reports reflecting the increasing experience of the teams, it clearly appears that the simplification of TAVI procedures has resulted in improved outcomes. We report here the case of a patient treated by means of a "minimalist" approach to TAVI allowing a reduction of the risks inherent in the procedure. This simplified strategy relies on an optimal use of CT scan findings prior to TAVI. The procedure is carried out under local anesthesia and the main access site is sutured percutaneously (Proglides). The radial artery is used as a secondary access site. Contrast medium is diluted and stimulation is administered via the intraventricular guidewire. Direct stenting is performed when deemed feasible on the basis of CT scan results. Simplified procedures such as these contribute to the improvement of TAVI outcomes. However, further studies focusing on female patients are warranted in order to corroborate these findings.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ancard.2016.10.016DOI Listing

Publication Analysis

Top Keywords

aortic stenosis
12
tavi procedure
8
aortic valve
8
female patients
8
access site
8
aortic
6
patients
5
tavi
5
[transfemoral tavi
4
women
4

Similar Publications

Aims: How the underlying etiology and pathophysiology of left ventricular (LV) hypertrophy affects LA remodeling and function remains unexplored. The present study aims to investigate the influence of various hypertrophic phenotypes on LA remodeling and function.

Methods And Results: Patients with LV hypertrophy who underwent cardiac magnetic resonance (CMR) were compared to a control group.

View Article and Find Full Text PDF

A Novel Staging System of Cardiac Damage in Aortic Stenosis based on Multi-Chamber Myocardial Deformation.

Eur Heart J Cardiovasc Imaging

January 2025

Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.

Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).

Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).

View Article and Find Full Text PDF

Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.

View Article and Find Full Text PDF

Re-sheathing failure with Navitor during transcatheter aortic valve implantation: a case report.

Eur Heart J Case Rep

January 2025

The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.

Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.

Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.

View Article and Find Full Text PDF

Fenestrated/branched endovascular aortic repair emerges as the primary therapeutic modality for intricate aortic pathologies encompassing the paravisceral and thoracoabdominal segments, where bridging stent grafts (BSGs) play a vital role in linking the primary aortic endograft with target vessels. Bridging stent grafts can be categorized mainly into self-expanding stent grafts (SESGs) and balloon-expandable stent grafts (BESGs). Physiological factors significantly influence post-complex endovascular aortic repair BSG behaviour, impacting clinical outcomes of SESGs and BESGs in different but overlapping ways.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!