Experiment for validation of fluid-structure interaction models and algorithms.

Int J Numer Method Biomed Eng

Division of Imaging Sciences and Biomedical Engineering, King's College London, 4th Floor, Lambeth Wing St. Thomas Hospital London, SE1 7EH, UK.

Published: September 2017

In this paper a fluid-structure interaction (FSI) experiment is presented. The aim of this experiment is to provide a challenging yet easy-to-setup FSI test case that addresses the need for rigorous testing of FSI algorithms and modeling frameworks. Steady-state and periodic steady-state test cases with constant and periodic inflow were established. Focus of the experiment is on biomedical engineering applications with flow being in the laminar regime with Reynolds numbers 1283 and 651. Flow and solid domains were defined using computer-aided design (CAD) tools. The experimental design aimed at providing a straightforward boundary condition definition. Material parameters and mechanical response of a moderately viscous Newtonian fluid and a nonlinear incompressible solid were experimentally determined. A comprehensive data set was acquired by using magnetic resonance imaging to record the interaction between the fluid and the solid, quantifying flow and solid motion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5600002PMC
http://dx.doi.org/10.1002/cnm.2848DOI Listing

Publication Analysis

Top Keywords

fluid-structure interaction
8
flow solid
8
experiment
4
experiment validation
4
validation fluid-structure
4
interaction models
4
models algorithms
4
algorithms paper
4
paper fluid-structure
4
interaction fsi
4

Similar Publications

This study addresses the challenges of electromagnetic interference and unstable signal transmission encountered by traditional sensors in detecting partial discharge (PD) within stator slots of large motors. A novel Extrinsic Fabry-Perot Interferometer (EFPI) sensor with a vibration-coupling air gap was designed to enhance the narrowband resonant detection sensitivity for PD ultrasonic signals by optimizing the diaphragm structure and coupling interface. The sensor features a quartz diaphragm with a thickness of 20 μM, an effective constrained radius of 0.

View Article and Find Full Text PDF

Impact of Vein Wall Hyperelasticity and Blood Flow Turbulence on Hemodynamic Parameters in the Inferior Vena Cava with a Filter.

Micromachines (Basel)

December 2024

Department of Cardiovascular Medicine, Heart, Vascular & Thoracic Institute, Cleveland Clinic, Cleveland, OH 44195, USA.

Inferior vena cava (IVC) filters are vital in preventing pulmonary embolism (PE) by trapping large blood clots, especially in patients unsuitable for anticoagulation. In this study, the accuracy of two common simplifying assumptions in numerical studies of IVC filters-the rigid wall assumption and the laminar flow model-is examined, contrasting them with more realistic hyperelastic wall and turbulent flow models. Using fluid-structure interaction (FSI) and computational fluid dynamics (CFD) techniques, the investigation focuses on three hemodynamic parameters: time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT).

View Article and Find Full Text PDF

Using bidirectional fluid-structure interaction technology, the dorsal-ventral motion of the dolphin tail fin was simulated, and the feasibility of the numerical simulation method was validated through underwater motion experiments. This study investigated the effects of structural parameters and motion modes of bionic dolphin tail fins on their propulsion performance. The results show that flexible tail fins can enhance propulsion performance.

View Article and Find Full Text PDF

Exploring the swimming performance and the physical mechanisms oflocomotion.

Bioinspir Biomim

January 2025

Mathematics and Statistics, College of New Jersey, 2000 Pennington Road, Ewing, New Jersey, 08628, UNITED STATES.

Tomopterids are mesmerizing holopelagic swimmers. They use two modes of locomotion simultaneously: drag-based metachronal paddling and bodily undulation.has two rows of flexible legs (parapodia) positioned on opposite sides of its body.

View Article and Find Full Text PDF

Background: High-field magnetic resonance imaging (MRI) is a powerful diagnostic tool but can induce unintended physiological effects, such as nystagmus and dizziness, potentially compromising the comfort and safety of individuals undergoing imaging. These effects likely result from the Lorentz force, which arises from the interaction between the MRI's static magnetic field and electrical currents in the inner ear. Yet, the Lorentz force hypothesis fails to explain observed eye movement patterns in healthy adults fully.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!