To reduce the production of wear particles and subsequent aseptic loosening, we created a human articular cartilage-mimicked surface for a highly cross-linked polyethylene liner, whose surface grafted layer consisted of a biocompatible phospholipid polymer, poly(2-methacryloyloxyethyl phosphorylcholine). Although our previous in vitro findings showed that poly(2-methacryloyloxyethyl phosphorylcholine)-grafted particles were biologically inert and caused no subsequent bone resorptive responses, and poly(2-methacryloyloxyethyl phosphorylcholine) grafting markedly decreased wear in hip joint simulator tests, the clinical safety, and in vivo wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners remained open to question. Therefore, in the present study, we evaluated clinical and radiographic outcomes of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners 5 years subsequent to total hip replacement in 68 consecutive patients. No reoperation was required for any reason, and no adverse events were associated with the implanted liners. The average Harris Hip Score increased from 38.6 preoperatively to 96.5 5 years postoperatively, and health-related quality of life, as indicated by the Short Form 36 Health Survey, improved. Radiographic analyses showed no periprosthetic osteolysis or implant migration. Between 1 and 5 years postoperatively, the mean steady-state wear rate was 0.002 mm/year, which represented a marked reduction relative to other highly cross-linked polyethylene liners, and appeared to be unaffected by patient-related or surgical factors. Although longer follow up is required, poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners improved mid-term clinical outcomes. The clinical safety and wear-resistance results are encouraging with respect to the improvement of long-term clinical outcomes with poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2007-2016, 2017.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jor.23473 | DOI Listing |
Gels
December 2024
School of Petrochemical Engineering & Environment, Zhejiang Ocean University, Zhoushan 316022, China.
Long-term polymer flooding exacerbates reservoir heterogeneity, intensifying intra- and inter-layer conflicts, which makes it difficult to recover the remaining oil. Therefore, further improvement in oil recovery after polymer flooding is essential. In this study, a weak gel system was successfully synthesized, and possesses a distinct network structure that becomes more compact as the concentration of partially hydrolyzed polyacrylamide increases.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
Department of Chemical Engineering, Guangdong Technion - Israel Institute of Technology, 241 Daxue Road, Shantou, Guangdong 515063, China.
Facilitated transport membranes (FTMs) with an ultraselective layer prepared from amine-rich polyvinylamine (PVAm)/2-(1-piperazinyl)ethylamine salt of sarcosine (PZEA-Sar) (denoted by PM) and an amorphous dendritic cross-linked network of PVAm-functionalized poly(ethylene glycol)diglycidyl ether (PEGDGE) (named PP) were designed for CO separations. The developed membranes expedited CO transport over N through the synergistic effect from the induced CO-philic ethylene oxide groups and highly hydrophilic and polar hydroxyl groups together with the low-crystallinity PP networks, which offer a high diffusion rate for CO-amine complexes through the membrane and stabilize small molecular mobile carriers via hydrogen bonding. The best (PM/PP-10)/polysulfone (PSf) composite membranes achieved a superior CO/N selectivity of 230 (4.
View Article and Find Full Text PDFInt J Biol Macromol
December 2024
College of Chemistry and Materials Engineering, Zhejiang A & F University, Hangzhou 311300, PR China. Electronic address:
Conductive hydrogels have been showcased with substantial potential for soft wearable devices. However, the tedious preparation process and poor trade-off among overall properties, i.e.
View Article and Find Full Text PDFAdv Ther (Weinh)
June 2024
Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty Mannheim, University of Heidelberg, Germany; Department of Otorhinolaryngology, Head and Neck Surgery, University Medical Center Mannheim, University of Heidelberg, Germany.
The gold standard of auricular reconstruction involves manual graft assembly from autologous costal cartilage. The intervention may require multiple surgical procedures and lead to donor-site morbidity, while the outcome is highly dependent on individual surgical skills. A tissue engineering approach provides the means to produce cartilage grafts of a defined shape from autologous chondrocytes.
View Article and Find Full Text PDFPeerJ
December 2024
Institute of Blood Transfusion, Chinese Academy of Medical Sciences & Peking Union Medical College, Chengdu, China.
Background: As a group of more than 3.67 million people, the bone health of Chinese plasmapheresis donors, which the main population is also a risk group of osteoporosis (OP), has raised concerns. Therefore, this article investigates the relationship between bone mineral density (BMD), bone metabolism indicators, and plasmapheresis donation behavior among some high-risk plasmapheresis donors for OP in China, and further explores the mediating factors through reasonable statistical methods.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!