Mouse models are increasingly employed in the comprehension of cardiovascular disease. Wave Intensity Analysis (WIA) can provide information about the interaction between the vascular and the cardiac system. We investigate age-associated changes in WIA-derived parameters in mice and correlate them with biomarkers of cardiac function. Sixteen wild-type male mice were imaged with high-resolution ultrasound (US) at 8 weeks (T ) and 25 weeks (T ) of age. Carotid pulse wave velocity (PWV) was calculated from US images using the diameter-velocity loop and employed to evaluate WIA. Amplitudes of the first (W ) and the second (W ) local maxima, local minimum (W ) and the reflection index (RI = W /W ) were assessed. Cardiac output (CO), ejection fraction (EF), fractional shortening (FS) and stroke volume (SV) were evaluated; longitudinal, radial and circumferential strain and strain rate values (LS, LSR, RS, RSR, CS, CSR) were obtained through strain analysis. W (T : 4.42e-07 ± 2.32e-07 m/s; T : 2.21e-07 ± 9.77 m/s), W (T : 2.45e-08 ± 9.63e-09 m/s; T : 1.78e-08 ± 7.82 m/s), W (T : -8.75e-08 ± 5.45e-08 m/s; T : -4.28e-08 ± 2.22e-08 m/s), CO (T : 19.27 ± 4.33 ml/min; T : 16.71 ± 2.88 ml/min), LS (T : 17.55 ± 3.67%; T : 15.05 ± 2.89%), LSR (T : 6.02 ± 1.39 s; T : 5.02 ± 1.25 s), CS (T : 27.5 ± 5.18%; T : 22.66 ± 3.09%) and CSR (T : 10.03 ± 2.55 s; T : 7.50 ± 1.84 s) significantly reduced with age. W was significantly correlated with CO (R = 0.58), EF (R = 0.72), LS (R = 0.65), LSR (R = 0.89), CS (R = 0.61), CSR (R = 0.70) at T ; correlations were lost at T . The decrease in W and W suggests a cardiac performance reduction, while that in W, considering unchanged RI, might indicate a wave energy decrease. The loss of correlation between WIA-derived and cardiac parameters might reflect an alteration in cardiovascular interaction.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-016-0914-yDOI Listing

Publication Analysis

Top Keywords

wave intensity
8
intensity analysis
8
cardiac
6
wave
4
analysis mice
4
mice age-related
4
age-related changes
4
changes wia
4
wia peaks
4
peaks correlation
4

Similar Publications

Hypotheses of pathophysiological mechanisms in epileptic encephalopathies: A review.

Brain Dev

January 2025

Department of Pediatric Neurology, Okayama University Hospital and Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan.

Introduction: Epileptic encephalopathy (EE) is a serious clinical issue that manifests as part of developmental and epileptic encephalopathy (DEE), particularly in childhood epilepsy. In EE, neurocognitive functions and behavior are impaired by intense epileptiform electroencephalogram (EEG) activity. Hypotheses of pathophysiological mechanisms behind EE are reviewed to contribute to an effective solution for EE.

View Article and Find Full Text PDF

Purpose: Eccentric calf training for Achilles tendinopathy shows variable success in athletes. Recent insights suggest a role for tendon fluid flow (exudation or redistribution) during exercise, which explains post-exercise reductions in thickness and increases in stiffness of the tendon. This fluid flow is thought to be beneficial as it may promote tendon remodeling, reduce intratendinous pressure, and alleviate pain.

View Article and Find Full Text PDF

Human mobility between different regions is a major factor in large-scale outbreaks of infectious diseases. Deep learning models incorporating infectious disease transmission dynamics for predicting the spread of multi-regional outbreaks due to human mobility have become a hot research topic. In this study, we incorporate the Graph Transformer Neural Network and graph learning mechanisms into a metapopulation SIR model to build a hybrid framework, Metapopulation Graph Transformer Neural Network (M-Graphormer), for high-dimensional parameter estimation and multi-regional epidemic prediction.

View Article and Find Full Text PDF

Purpose: To assess the safety of acoustic radiation force optical coherence elastography in the crystalline lens in situ.

Methods: Acoustic radiation force (ARF) produced by an immersion single-element ultrasound transducer (nominal frequency = 3.5 MHz) was characterized using a needle hydrophone and used for optical coherence elastography (OCE) of the crystalline lens.

View Article and Find Full Text PDF

Acute Kidney Injury (AKI) is a significant medical condition characterized by the abrupt decline in kidney function.Low-intensity pulsed ultrasound (LIPUS), a non-invasive therapeutic technique employing low-intensity acoustic wave pulses, has shown promise in promoting tissue repair and regeneration. A novel LIPUS system was developed and evaluated in rat AKI models, focusing on its effects on glomerular filtration rate (GFR), blood urea nitrogen (BUN), serum creatinine (SCr), and the Notch1-Akt-eNOS signaling pathway.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!