A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Patient-related quality assurance with different combinations of treatment planning systems, techniques, and machines : A multi-institutional survey. | LitMetric

Purpose: This project compares the different patient-related quality assurance systems for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques currently used in the central Germany area with an independent measuring system.

Materials And Methods: The participating institutions generated 21 treatment plans with different combinations of treatment planning systems (TPS) and linear accelerators (LINAC) for the QUASIMODO (Quality ASsurance of Intensity MODulated radiation Oncology) patient model. The plans were exposed to the ArcCHECK measuring system (Sun Nuclear Corporation, Melbourne, FL, USA). The dose distributions were analyzed using the corresponding software and a point dose measured at the isocenter with an ionization chamber.

Results: According to the generally used criteria of a 10 % threshold, 3 % difference, and 3 mm distance, the majority of plans investigated showed a gamma index exceeding 95 %. Only one plan did not fulfill the criteria and three of the plans did not comply with the commonly accepted tolerance level of ±3 % in point dose measurement.

Conclusion: Using only one of the two examined methods for patient-related quality assurance is not sufficiently significant in all cases.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00066-016-1064-yDOI Listing

Publication Analysis

Top Keywords

quality assurance
16
patient-related quality
12
combinations treatment
8
treatment planning
8
planning systems
8
assurance
4
assurance combinations
4
systems techniques
4
techniques machines
4
machines a multi-institutional
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!