Background: Ingestion of foreign bodies and food impaction represent the second most common endoscopic emergency after bleeding. The aim of this paper is to report the management and the outcomes in 67 patients admitted for suspected ingestion of foreign body between December 2012 and December 2014.
Methods: This retrospective study was conducted at Palermo University Hospitals, Italy, over a 2-year period. We reviewed patients' database (age, sex, type of foreign body and its anatomical location, treatments, and outcomes as complications, success rates, and mortalities).
Results: Foreign bodies were found in all of our 67 patients. Almost all were found in the stomach and lower esophagus (77 %). The types of foreign body were very different, but they were chiefly meat boluses, fishbones or cartilages, button battery and dental prostheses. In all patients it was possible to endoscopically remove the foreign body. Complications related to the endoscopic procedure were unfrequent (about 7 %) and have been treated conservatively. 5.9 % of patients had previous esophageal or laryngeal surgery, and 8.9 % had an underlying esophageal disease, such as a narrowing, dismotility or achalasia.
Conclusion: Our experience with foreign bodies and food impaction emphasizes the importance of endoscopic approach and removal, simple and secure when performed by experienced hands and under conscious sedation in most cases. High success rates, lower incidence of minor complications, reduction of the need of surgery and reduced hospitalization time are the strengths of the endoscopic approach.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5095952 | PMC |
http://dx.doi.org/10.1186/s12873-016-0104-3 | DOI Listing |
J Pediatr Ophthalmol Strabismus
January 2025
This report describes the longest case of a retained metallic intraorbital foreign body with no complications and development of delayed sensory exotropia following traumatic sclopetaria in childhood. A 9-year-old girl suffered a BB gun injury to the left eye, leading to chorioretinitis sclopetaria and loss of vision. The visual acuity was 20/800 with a relative afferent pupillary defect and choroidal rupture with subretinal hemorrhage that evolved to sclopetaria over time.
View Article and Find Full Text PDFCureus
December 2024
Department of Orthopedic Surgery, Japanese Red Cross Shizuoka Hospital, Shizuoka, JPN.
Total hip arthroplasty (THA) is a highly effective surgical intervention for end-stage hip joint disorders. While common complications such as infection, dislocation, and prosthetic loosening are well-documented, rarer complications remain underreported. One such complication is foreign body interposition on the bearing surface, which can compromise joint mechanics and adversely affect outcomes.
View Article and Find Full Text PDFBMJ Case Rep
January 2025
Pneumology, Centre Hospitalier du Valais Romand, Sion, Switzerland.
A woman in her mid-70s presented with worsening dyspnoea, cough and fatigue initially treated for pneumonia. Despite antibiotics, her condition deteriorated, prompting further investigation. Medical history included previous breast implants, the latter of which had ruptured years earlier and was subsequently removed prior to the current presentation.
View Article and Find Full Text PDFCureus
December 2024
Department of Pulmonary Medicine, All India Institute of Medical Sciences, Jodhpur, Jodhpur, IND.
Background Airway foreign body aspiration is an emergency predominantly observed in children and the elderly. However, it also occurs in adults, presenting with a variety of symptoms. Both rigid and flexible bronchoscopies are employed for foreign body retrieval.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
January 2025
From the Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA (Colin M Segovis), Department of Neuroradiology, University of Texas MD Anderson Cancer Center, Houston, Texas, USA (Jacob W Ormsby, Melissa M Chen), Department of Radiology, Indiana University School of Medicine, Indianapolis, IN, USA (Cindy X Yuan), Enterprise Radiology, Emory Healthcare, Atlanta, GA, USA (Matthew J Goette), Department of Radiology, Mayo Clinic, Rochester, MN, USA (Heidi A Edmonson).
The magnetic fields of the MR environment present unique safety challenges. Medical implants and retained foreign bodies can prevent patients from undergoing MR imaging due to interactions between the magnetic fields of the MR environment and the implant or foreign body. These hazards can be addressed through careful MR safety screening and MR examination customization, often allowing these patients with implants to undergo management-altering MR imaging.