Modelling and simulation has been used in many ways when developing new treatments. To be useful and credible, it is generally agreed that modelling and simulation should be undertaken according to some kind of best practice. A number of authors have suggested elements required for best practice in modelling and simulation. Elements that have been suggested include the pre-specification of goals, assumptions, methods, and outputs. However, a project that involves modelling and simulation could be simple or complex and could be of relatively low or high importance to the project. It has been argued that the level of detail and the strictness of pre-specification should be allowed to vary, depending on the complexity and importance of the project. This best practice document does not prescribe how to develop a statistical model. Rather, it describes the elements required for the specification of a project and requires that the practitioner justify in the specification the omission of any of the elements and, in addition, justify the level of detail provided about each element. This document is an initiative of the Special Interest Group for modelling and simulation. The Special Interest Group for modelling and simulation is a body open to members of Statisticians in the Pharmaceutical Industry and the European Federation of Statisticians in the Pharmaceutical Industry. Examples of a very detailed specification and a less detailed specification are included as appendices.

Download full-text PDF

Source
http://dx.doi.org/10.1002/pst.1789DOI Listing

Publication Analysis

Top Keywords

modelling simulation
28
best practice
16
elements required
8
level detail
8
special interest
8
interest group
8
group modelling
8
statisticians pharmaceutical
8
pharmaceutical industry
8
detailed specification
8

Similar Publications

In this study, a new deterministic mathematical model based on fractional-order derivative operator that describes the pseudo-recovery dynamics of an epidemiological process is developed. Fractional-order derivative of Caputo type is used to examine the effect of memory in the spread process of infectious diseases with pseudo-recovery. The well-posedness of the model is qualitatively investigated through Banach fixed point theory technique.

View Article and Find Full Text PDF

This study presents an advanced dynamic finite element (FE) model of multiple components of the breast to examine the biomechanical impact of different types of physical activities and activity intensity on the breast tissues. Using 4D scanning and motion capture technologies, dynamic data are collected during different activities. The accuracy of the FE model is verified based on relative mean absolute error (RMAE), and optimal material parameters are identified by using a validated stepwise grid search method.

View Article and Find Full Text PDF

Street-scale black carbon modelling over the West Midlands, United Kingdom: Sensitivity test of traffic emission factor adjustments.

Environ Int

January 2025

School of Geography, Earth & Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK; Department of Environmental Sciences/Center of Excellence in Environmental Studies, King Abdulaziz University, PO Box 80203, Jeddah 21589, Saudi Arabia. Electronic address:

Black carbon is harmful for climate, environment, and human health. Road traffic is one of the major sources for black carbon in urban areas. This study develops a street scale air quality model configuration for the dispersion of black carbon concentrations across the West Midlands, UK, incorporating updated road traffic emission factors.

View Article and Find Full Text PDF

In a rapidly evolving healthcare environment, artificial intelligence (AI) is transforming diagnostic techniques and personalised medicine. This is also seen in osseous biopsies. AI applications in radiomics, histopathology, predictive modelling, biopsy navigation, and interdisciplinary communication are reshaping how bone biopsies are conducted and interpreted.

View Article and Find Full Text PDF

Background: Tranexamic acid is an anti-fibrinolytic agent routinely used during hip and knee joint replacement surgery to minimize bleeding. Chronic kidney disease is a common chronic health problem seen among adults requiring major arthroplasty surgery. Tranexamic acid is renally cleared and may accumulate in chronic kidney disease.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!