Background: The advent of adverse local tissue reactions seen in metal-on-metal bearings, and the recent recognition of trunnionosis, have led many surgeons to recommend ceramic-on-polyethylene articulations for primary total hip arthroplasty. However, to our knowledge, there has been little research that has considered whether the increased cost of ceramic provides enough benefit over cobalt-chromium to justify its use. The primary purpose of this study was to compare the cost-effectiveness of ceramic-on-polyethylene implants and metal-on-polyethylene implants in patients undergoing total hip arthroplasty.
Methods: Markov decision modeling was used to determine the ceramic-on-polyethylene implant revision rate necessary to be cost-effective compared with the revision rate of metal-on-polyethylene implants across a range of patient ages and implant costs. A different set of Markov models was used to estimate the national cost burden of choosing ceramic-on-polyethylene implants over metal-on-polyethylene implants for primary total hip arthroplasties. The Premier Research Database was used to identify 20,398 patients who in 2012 were ≥45 years of age and underwent a total hip arthroplasty with either a ceramic-on-polyethylene implant or a metal-on-polyethylene implant.
Results: The cost-effectiveness of ceramic heads is highly dependent on the cost differential between ceramic and metal femoral heads and the age of the patient. At a cost differential of $325, ceramic-on-polyethylene bearings are cost-effective for patients <85 years of age. At a cost differential of $600, it is cost-effective to utilize ceramic-on-polyethylene bearings in patients <65 years of age, and, at a differential of $1,003, ceramic-on-polyethylene bearings are not cost-effective at any age.
Conclusions: The ability to recoup the initial increased expenditure of ceramic heads through a diminished lifetime revision cost is dependent on the price premium for ceramic and the age of the patient. A wholesale switch to ceramic bearings regardless of age or cost differential may result in an economic burden to the health system.
Level Of Evidence: Economic and decision analysis, Level III. See Instructions for Authors for a complete description of levels of evidence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2106/JBJS.15.00831 | DOI Listing |
J Mech Behav Biomed Mater
January 2025
Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada; Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada. Electronic address:
Background: The risk of early revision of total hip arthroplasty (THA) for polyethylene wear is now low, but there remains a need to perform wear measurements in patients for clinical surveillance. The gold standard of wear measurements has been radiostereometric analysis (RSA), which has limited availability. The use of computed tomography (CT) to perform THA wear measurement was described a decade ago and found to have acceptable accuracy and precision, but high radiation dose was a concern.
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2025
Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, USA.
Introduction: Knee alignment significantly impacts the outcome of total knee arthroplasty (TKA). Understanding patient perceptions of their knee alignment in relation to objective measurements is essential to ensure optimal surgical outcomes and to meet patients' expectations. This study reports patients' perception of pre- and postoperative knee alignment in relation to radiographic alignment measurements.
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2025
Centre Hospitalier Universitaire de Nîmes, Nîmes, France.
Purpose: The adoption of robotic-assisted total hip arthroplasty (THA) is increasingly widespread, yet its influence on outcomes in outpatient surgery remains uncertain. This study aimed to evaluate whether robotic assistance reduces the rate of 90-day postoperative events in patients undergoing outpatient THA, compared to those in inpatient procedures.
Methods: This historical-prospective cohort study analyzed 706 primary THA cases performed between January 2017 and January 2023 by three senior surgeons.
J Shoulder Elbow Surg
January 2025
Roth | McFarlane Hand & Upper Limb Center, St Joseph's Health Care London, London, ON, Canada.
Background: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control.
View Article and Find Full Text PDFAm J Sports Med
January 2025
Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA.
Background: Intraoperative hip capsule management is increasingly recognized as an important component of hip arthroscopy for the prevention of capsular-related instability. The periportal capsulotomy, relative to the interportal capsulotomy, has been proposed as a minimally invasive technique for decreasing postarthroscopy hip instability; however, the biomechanical effects of this technique are not well established.
Purpose/hypothesis: This study aimed to provide a biomechanical characterization of interportal and periportal capsulotomies, helping inform surgeon choice of capsulotomy type and repair, potentially guiding clinical practice in hip arthroscopy.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!