ITER-like antenna capacitors voltage probes: Circuit/electromagnetic calculations and calibrations.

Rev Sci Instrum

EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB, United KingdomCEA, IRFM, F-13108 St-Paul-Lez-Durance, FranceLPP-ERM/KMS, TEC partner, Brussels, BelgiumCCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.

Published: October 2016

The analyses illustrated in this manuscript have been performed in order to provide the required data for the amplitude-and-phase calibration of the D-dot voltage probes used in the ITER-like antenna at the Joint European Torus tokamak. Their equivalent electrical circuit has been extracted and analyzed, and it has been compared to the one of voltage probes installed in simple transmission lines. A radio-frequency calibration technique has been formulated and exact mathematical relations have been derived. This technique mixes in an elegant fashion data extracted from measurements and numerical calculations to retrieve the calibration factors. The latter have been compared to previous calibration data with excellent agreement proving the robustness of the proposed radio-frequency calibration technique. In particular, it has been stressed that it is crucial to take into account environmental parasitic effects. A low-frequency calibration technique has been in addition formulated and analyzed in depth. The equivalence between the radio-frequency and low-frequency techniques has been rigorously demonstrated. The radio-frequency calibration technique is preferable in the case of the ITER-like antenna due to uncertainties on the characteristics of the cables connected at the inputs of the voltage probes. A method to extract the effect of a mismatched data acquisition system has been derived for both calibration techniques. Finally it has been outlined that in the case of the ITER-like antenna voltage probes can be in addition used to monitor the currents at the inputs of the antenna.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4964137DOI Listing

Publication Analysis

Top Keywords

voltage probes
20
iter-like antenna
16
calibration technique
16
radio-frequency calibration
12
calibration
8
case iter-like
8
voltage
5
probes
5
technique
5
iter-like
4

Similar Publications

The transmembrane potential of plasma membranes and membrane-bound organelles plays a fundamental role in cellular functions such as signal transduction, ATP synthesis, and homeostasis. Rhodamine voltage reporters (RhoVRs), which operate based on the photoinduced electron transfer (PeT) mechanism, are non-invasive, small-molecule voltage sensors that can detect rapid voltage changes, with some of them specifically targeting the inner mitochondrial membrane. In this work, we conducted extensive molecular dynamics simulations and free-energy calculations to investigate the physicochemical properties governing the orientation as well as membrane permeation barriers of three RhoVRs.

View Article and Find Full Text PDF

Neuroendocrine cells react to physical, chemical, and synaptic signals originating from tissues and the nervous system, releasing hormones that regulate various body functions beyond the synapse. Neuroendocrine cells are often embedded in complex tissues making direct tests of their activation mechanisms and signaling effects difficult to study. In the nematode worm , four uterine-vulval (uv1) neuroendocrine cells sit above the vulval canal next to the egg-laying circuit, releasing tyramine and neuropeptides that feedback to inhibit egg laying.

View Article and Find Full Text PDF

Smart delivery materials that respond to electric fields attract interest across various fields, whereas systems enabling rapid, controllable, and safe delivery capabilities remain essential. Based on the hypothesis of utilizing electric field to manipulate inter-component noncovalent bonds in delivery materials, a hydrogel system is hereby reported that is capable of achieving rapid guest release at low-voltage region. This system harnesses the synergistic regulation of electric field-induced host-guest electrostatic repulsion, alongside the dynamic modulation of H-bond interactions within the conductive hydrogel.

View Article and Find Full Text PDF

Ultrasound-induced thermal strain imaging (US-TSI) is a promising ultrasound imaging modality that has been demonstrated in preclinical studies to identify a lipid-rich necrotic core of an atherosclerotic plaque. However, human physiological motion, e.g.

View Article and Find Full Text PDF
Article Synopsis
  • Single cell calcium (Ca) imaging, utilizing microscopy and the Fura-2/AM indicator, is crucial for studying Ca channels activated by various stimuli.
  • When Fura-2/AM enters cells, it is converted to Fura-2, which binds calcium and shows a measurable change in fluorescence based on calcium concentration.
  • This method allows for real-time monitoring of Ca changes across multiple cells, facilitating efficient data analysis and improving understanding of calcium signaling in cells.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!