An X-ray reflectometer (XRR) system has been developed at the Marshall Space Flight Center (MSFC) for characterizing various soft and hard X-ray optic coatings. The XRR instrument generates X-ray radiation using a high-output rotating anode source (RAS), operational over a voltage range of 5-35 kV and a current range of 10-150 mA. Copper is used as the target material to produce an X-ray spectrum from which the K line at 8.048 keV is isolated for the reflectivity measurements. Five precision slits are mounted along the X-ray beam path to limit the extent of the beam at the sample and to adjust the resolution in the measurements. A goniometer consisting of two precision rotary stages controls the positions of the coating sample and the X-ray detector with respect to the beam. The detector itself is a high performance silicon drift detector used to achieve high count rate efficiency to attain good statistics in the reflectivity measurement at larger grazing angles. The X-ray reflectometer system design and capabilities are described in detail. Verification of the system is obtained through an interlaboratory study in which reflectivity measurements of a multilayer coating made at MSFC are compared with those made at two external laboratories.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.4965978 | DOI Listing |
Rev Sci Instrum
February 2024
Accelerator Physics and Synchrotrons Utilization Division, Raja Ramanna Centre for Advanced Technology, Indore 452 013, India.
A versatile beamline for performing reflectivity, fluorescence, and absorption experiments in the soft x-ray region of 100-1500 eV is commissioned on a bending magnet port of the Indus-2 synchrotron source. A high vacuum 2-axis reflectometer with x, y, and z sample scanning stages is installed. This reflectometer is used to measure the reflectivity of large samples up to 300 mm in length and 5 kg in weight.
View Article and Find Full Text PDFBMC Neurol
August 2023
School of Mental Health and Neuroscience (MHeNs), University Eye Clinic Maastricht, Maastricht University, Maastricht, The Netherlands.
Background: Alzheimer's disease (AD) is the most common cause of dementia, and due to increasing life expectancy the number of patients is expected to grow. The diagnosis of AD involves the use of biomarkers determined by an amyloid PET scan or cerebrospinal fluid analyses that are either invasive or expensive, and not available in each hospital, thus limiting their usage as a front-line screener. The TearAD study aims to use tear fluid as a potential source for AD biomarkers.
View Article and Find Full Text PDFJ Biomed Opt
June 2022
University of Southern California, Department of Biomedical Engineering, Los Angeles, California, United States.
Significance: We present an approach to estimate with simple instrumentation the amount of red blood cells in the skin microvasculature, designated as parameter LRBC. Variations of parameter LRBC are shown to reflect local changes in the quantity of skin red blood cells during a venous occlusion challenge.
Aim: To validate a simple algebraic model of light transport in skin using the Monte Carlo method and to develop a measure of the red blood cell content in skin microvessels using the Monte Carlo predictions; to guide the development of an instrument to measure experimentally variations of the amount of red blood cells in the skin.
Struct Dyn
May 2021
Sorbonne Université, CNRS, Laboratoire de Chimie Physique-Matière et Rayonnement, 75005 Paris, France.
During the last two decades, a variety of models have been developed to explain the ultrafast quenching of magnetization following femtosecond optical excitation. These models can be classified into two broad categories, relying either on a local or a non-local transfer of angular momentum. The acquisition of the magnetic depth profiles with femtosecond resolution, using time-resolved x-ray resonant magnetic reflectivity, can distinguish local and non-local effects.
View Article and Find Full Text PDFNumerical and experimental studies have been performed to evaluate the enhancement of diffraction efficiency of diffraction gratings around B $K$-emission by overcoating lanthanum series layers on conventional metal-coated laminar-type gratings. We propose an optical design method based on the concept of spectral flux given by collection efficiency and diffraction efficiency. A diffraction grating with a small angle of incidence provides an advantage to soft x-ray spectrographs because it collects the emission at a larger solid angle compared to that of conventional grazing incidence diffraction gratings.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!