AI Article Synopsis

  • High precision optical beam measurements are crucial for applications in fields like sensing and atomic force microscopy.
  • A new measurement technique uses a scanning quadrant photodiode (QPD) and low-noise electronics to directly read the shifts between a signal beam and a reference beam.
  • The method incorporates polarization multiplexing to achieve an accuracy of 150 nm while measuring the Goos-Hänchen shift of a beam reflecting off a gold surface.

Article Abstract

High precision measurements of optical beam shifts are important in various fields including sensing, atomic force microscopy, and measuring beam shifts at interfaces. Sub-micron shifts are generally measured by indirect techniques such as weak measurements. We demonstrate a straightforward and robust measurement scheme for the shift, based on a scanning quadrant photodiode (QPD) that is biased using a low noise electronic circuit. The shift is measured with respect to a reference beam that is co-propagating with the signal beam. Thus, the shift of the signal beam is readout directly as the difference between the x-intercepts of the QPD scan plot of the signal and reference beams versus the position of the detector. To measure the beam shift, we use polarization multiplexing scheme where the p-polarized signal and s-polarized reference beams are modulated at two different frequencies and co-launched into a polarization-maintaining fiber. Both the signal and reference beam positions are readout by two lock-in amplifiers simultaneously. In order to demonstrate the utility of this method, we perform a direct measurement of Goos-Hänchen shift of a beam that is reflected from a plane gold surface. Accuracy of 150 nm is achieved using this technique.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4964730DOI Listing

Publication Analysis

Top Keywords

direct measurement
8
measurement goos-hänchen
8
goos-hänchen shift
8
scanning quadrant
8
beam
8
beam shifts
8
reference beam
8
signal beam
8
beam shift
8
signal reference
8

Similar Publications

: External factors can disrupt postural control, but the intricate workings of the postural control system enable an appropriate response. This study seeks to assess how external perturbations affect postural control. : Twenty women participated in study, which consisted four trials involved quiet standing and experiencing induced perturbations by being struck with a boxing bag from the back, right, and left sides, respectively.

View Article and Find Full Text PDF

Bacterial infections pose a serious threat to human health. For many years, there has been a search for materials that would inhibit their development. It was decided to take a closer look at various elastomeric materials with the addition of chitosan.

View Article and Find Full Text PDF

: This study aimed to investigate the differences in spatiotemporal gait parameters in patients who underwent surgery for hip fractures when using walking poles and T-canes. : This cross-sectional study enrolled eight patients who underwent surgery for a unilateral hip fracture (mean age of 79.0 ± 7.

View Article and Find Full Text PDF

H*10 neutron dosimetry (unlike gamma dosimetry), requires consideration of neutron energy spectra due to the 20× variation of the weight factor over the thermal-to-fast energy range, as well as the neutron radiation field dose rates ranging from cosmic, ~.01 μSv h-1 levels to commonly encountered ~10-200 μSv h-1 in nuclear laboratories/processing plants, and upwards of 104 Sv h-1 in nuclear reactor environments. This paper discusses the outcome of the comparison of spectrum-weighted neutron dosimetry covering thermal-to-fast energy using the novel H*-TMFD spectroscopy-enabled sensor system in comparison with measurements using state-of-the-art neutron dosimetry systems at SRNS-Rotating Spectrometer (ROSPEC), and non-spectroscopic Eberline ASP2E ("Eberline") and Ludlum 42-49B ("Ludlum") survey instrumentation.

View Article and Find Full Text PDF

Objective: To examine the association between serum thyroid-stimulating hormone (TSH) levels with handgrip strength (HGS) and dynapenia in euthyroid postmenopausal women.

Methods: This was an exploratory cross-sectional study among 385 participants from the Department of Obstetrics, Gynecology, and Reproduction of the Dexeus Women's University Hospital, Barcelona, Spain. Age, age at menopause, adiposity, alcohol consumption, body mass index (BMI), and smoking status were recorded.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!