A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Heparin Isomeric Oligosaccharide Separation Using Volatile Salt Strong Anion Exchange Chromatography. | LitMetric

Heparin Isomeric Oligosaccharide Separation Using Volatile Salt Strong Anion Exchange Chromatography.

Anal Chem

Centre for Glycobiology, Department of Biochemistry, Institute of Integrative Biology, University of Liverpool, Crown Street, Liverpool L69 7ZB, United Kingdom.

Published: December 2016

The complexity of heparin and heparan sulfate saccharides makes their purification, including many isomeric structures, very challenging and is a bottleneck for structure-activity studies. High-resolution separations have been achieved by strong anion exchange (SAX) chromatography on Propac PA1 and cetyltrimethylammonium (CTA)-C silica columns; however, these entail subsequent desalting methodologies and consequent sample losses and are incompatible with orthogonal chromatography methodologies and, in particular, mass spectrometry. Here, we present the CTA-SAX purification of heparin oligosaccharides using volatile salt (VS) buffer. In VSCTA-SAX, the use of ammonium bicarbonate buffer for elution improves resolution through both weaker dissociation and conformational coordination of the ammonium across the sulfate groups. Using ion mobility mass spectrometry, we demonstrate that isomeric structures have different structural conformations, which makes chromatographic separation achievable. Resolution of such structures is improved compared to standard SAX methods, and in addition, VSCTA-SAX provides an orthogonal method to isolate saccharides with higher purity. Because ammonium bicarbonate is used, the samples can be evaporated rather than desalted, preventing substantial sample loss and allowing more effective subsequent analysis by electrospray mass spectrometry. We conclude that VSCTA-SAX is a powerful new tool that helps address the difficult challenge of heparin/heparan sulfate saccharide separation and will enhance structure-activity studies.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.6b02801DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
12
volatile salt
8
strong anion
8
anion exchange
8
isomeric structures
8
structure-activity studies
8
ammonium bicarbonate
8
heparin isomeric
4
isomeric oligosaccharide
4
oligosaccharide separation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!