A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The efficacy of semi-quantitative urine protein-to-creatinine (P/C) ratio for the detection of significant proteinuria in urine specimens in health screening settings. | LitMetric

Background: Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods.

Methods: Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed.

Results: In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests.

Conclusions: The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5063823PMC
http://dx.doi.org/10.1186/s40064-016-3389-5DOI Listing

Publication Analysis

Top Keywords

p/c ratio
32
urine protein
16
semi-quantitative p/c
16
urine
13
semi-quantitative urine
12
urine samples
12
efficacy semi-quantitative
8
urine protein-to-creatinine
8
p/c
8
protein-to-creatinine p/c
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!