The sensitivity and efficiency in contrast-enhanced ultrasound imaging and therapy can potentially be increased by the use of resonant monodisperse bubbles. However, bubbles of the same size may respond differently to ultrasound due to differences in their phospholipid shell. In an acoustic bubble sorting chip, resonant bubbles can be separated from the polydisperse agent. Here, a sample of acoustically sorted bubbles is characterized by measuring scattering and attenuation simultaneously using narrowband acoustic pulses at peak negative pressures of 10, 25, and 50 kPa over a 0.7-5.5 MHz frequency range. A second sample is characterized by attenuation measurements at acoustic pressures ranging from 5 to 75 kPa in steps of 2.5 kPa. Scattering and attenuation coefficients were modeled by integration over the pressure and frequency dependent response of all bubbles located within the non-uniform acoustic characterization beam. For all driving pressures and frequencies employed here, the coefficients could be modeled using a single and unique set of shell parameters confirming that acoustically sorted bubbles provide a uniform acoustic response. Moreover, it is shown that it is crucial to include the pressure distribution of the acoustic characterization beam in the modeling to accurately determine shell parameters of non-linearly oscillating bubbles.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1121/1.4964270 | DOI Listing |
Sensors (Basel)
December 2024
School of Pharmacy, Guangdong Pharmaceutical University, Guangzhou 510006, China.
Curcumae Longae Rhizoma (CLRh), Curcumae Radix (CRa), and Curcumae Rhizoma (CRh), derived from the different medicinal parts of the species, are blood-activating analgesics commonly used for promoting blood circulation and relieving pain. Due to their certain similarities in chemical composition and pharmacological effects, these three herbs exhibit a high risk associated with mixing and indiscriminate use. The diverse methods used for distinguishing the medicinal origins are complex, time-consuming, and limited to intraspecific differentiation, which are not suitable for rapid and systematic identification.
View Article and Find Full Text PDFAntioxidants (Basel)
November 2024
Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104, USA.
The direct detection of singlet-state oxygen (O) constitutes the holy grail dosimetric method for type-II photodynamic therapy (PDT), a goal that can be quantified using multispectral singlet oxygen near-infrared luminescence dosimetry (MSOLD). The optical properties of tissues, specifically their scattering and absorption coefficients, play a crucial role in determining how the treatment and luminescence light are attenuated. Variations in these properties can significantly impact the spatial distribution of the treatment light and hence the generation of singlet oxygen and the detection of singlet oxygen luminescence signals.
View Article and Find Full Text PDFMed Phys
January 2025
Breast Imaging Department, Red Cross Hospital Munich, Munich, Germany.
Background: A significant proportion of false positive recalls of mammography-screened women is due to benign breast cysts and simple fibroadenomas. These lesions appear mammographically as smooth-shaped dense masses and require the recalling of women for a breast ultrasound to obtain complementary imaging information. They can be identified safely by ultrasound with no need for further assessment or treatment.
View Article and Find Full Text PDFAm J Ophthalmol Case Rep
December 2024
Genomic Laboratory, Umraniye Training and Research Hospital, University of Health Sciences, Istanbul, Turkey.
Optica
December 2024
Department of Medical Physics and Biomedical Engineering, University College London, London, WC1E 6BT, UK.
X-ray dark-field imaging highlights sample structures through contrast generated by sub-resolution features within the inspected volume. Quantifying dark-field signals generally involves multiple exposures for phase retrieval, separating contributions from scattering, refraction, and attenuation. Here, we introduce an approach for non-interferometric X-ray dark-field imaging that presents a single-parameter representation of the sample.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!